[Bldg-sim] Easy Question

Wilson, Luke LWilson at integral-group.net
Tue Apr 13 08:18:15 PDT 2010


John,

I'm assuming you are using ASHRAE 90.1-2007 Appendix G for your Baseline?
If so, the way I read it from Table G3.1 is that you should evenly distribute the WWR of the entire building, not for each floor. Therefore I would use 11.4% for each floor.

Luke

-----Original Message-----
From: bldg-sim-bounces at lists.onebuilding.org [mailto:bldg-sim-bounces at lists.onebuilding.org] On Behalf Of Eurek, John S NWO
Sent: Tuesday, April 13, 2010 10:22 AM
To: bldg-sim at lists.onebuilding.org
Subject: [Bldg-sim] Easy Question

I have a two story building.  For the baseline I am evenly distributing the
fenestration.

The first floor window area is 462.2 ft^2
The second floor window area is 647.1 ft^2

The first floor wall area is 4858 ft^2
The second floor wall area is 4858 ft^2

In the base line model do I use:

First floor 9.5%
Second floor 13.3%

OR

First floor 11.4%
Second floor 11.4%
_______________________________________________
Bldg-sim mailing list
http://lists.onebuilding.org/listinfo.cgi/bldg-sim-onebuilding.org
To unsubscribe from this mailing list send  a blank message to BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG


This email and any files transmitted with it are confidential and intended solely for the addressee.  If you are not the named addressee you should not disseminate, distribute, copy, or alter this email.