[Bldg-sim] Exhaust fans

Rathna Shree rathnashreep at yahoo.in
Wed Apr 18 01:33:48 PDT 2012


I am thinking of taking it as a miscellaneous load as the warehouse is not conditioned. Thank you all for the inputs.

Regards,
Rathnashree



________________________________
 From: Ashraf Khan <p.ashraf at aesg-me.com>
To: 'jorge torres coto' <jorgembo1 at gmail.com>; 'Rathna Shree' <rathnashreep at yahoo.in> 
Cc: 'bldg' <bldg-sim at lists.onebuilding.org> 
Sent: Wednesday, 18 April 2012 11:53 AM
Subject: RE: [Bldg-sim] Exhaust fans
 

 
I had similar project earlier. In my energy model, I considered
warehouse power as miscellaneous equipment load and USGBC has no problem accepting
it.
In future if you got project as warehouse conditioned, then definitely
you should model as exhaust fans. 
 
Regards,
 
Ashraf Ali Khan
BE (Mech), LEED AP, PQP
Sustainability Consultant
 
AESG
P.O. Box 1626
Dubai
U.A.E.
Office: +971 (0) 4 354 8883
Mobile: +971 (0) 50 155 7012
www.aesg-me.com
 http://www.linkedin.com/pub/ashraf-ali-khan-energy-modeler-leed-ap-pqp/21/2b3/63a
Please consider the environment before printing this e-mail
 
The information transmitted is intended only for the person or
entity to which it is addressed and may contain confidential and/or privileged
material. Any review, retransmission, dissemination or other use of, or taking
of any action in reliance upon, this information by persons or entities other
than the intended recipient is prohibited. If you received this in error,
please contact the sender and delete the material from any computer.
 
From:jorge torres coto
[mailto:jorgembo1 at gmail.com] 
Sent: Tuesday, April 17, 2012 6:20 AM
To: Rathna Shree
Cc: bldg
Subject: Re: [Bldg-sim] Exhaust fans
 
Easiest is just airflows, bhp, etc
Or you can model an hvac unit with 0 capacity for both heating an cooling and
setpoints equal to design outside air
On Apr 16, 2012 3:34 AM,
"Rathna Shree" <rathnashreep at yahoo.in>
wrote:
>Dear All,
> 
>I am working
on a warehouse project. Warehouse areas are non conditioned and these areas
have exhaust fans. Please let me know how to model these fans. Can i just treat
it as an miscellaneous equipment load? Is it required to model with fan air
volume, bhp etc.
> 
>Regards,
>Rathnashree
>
>_______________________________________________
>Bldg-sim mailing list
>http://lists.onebuilding.org/listinfo.cgi/bldg-sim-onebuilding.org
>To unsubscribe from this mailing list send  a blank message to BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/bldg-sim-onebuilding.org/attachments/20120418/a564662e/attachment-0002.htm>


More information about the Bldg-sim mailing list