I am having some difficulty setting up multiple HVAC systems serving one zone. 
The situation is that I am modeling a building with packaged rooftop units as
well as exhaust fans. However, I can't model the exhaust fans using the exhaust
fan object because the exhaust fans are controlled based on enthalpy
differential with outdoor air (as I understand it, exhaust fan availability
managers only allow temperature differential).

So I thought I would set up another HVAC system in addition to the RTUs that
would function like the exhaust fans (with a supply fan, rather than exhaust, no
heating or cooling coils). I could then use an outside air controller to
specify the enthapy differential control. The issue I am having is setting up
both systems to serve one zone. Do I connect the second system (exhaust
system)to the zone inlet node, or upstream of the zone splitter associated with
the RTUs? Where do I connect downstream of the zone?

Any help would be much appreciated. Of course, if anyone has a way of getting
the exhaust fan object to run on differential enthalpy, I would take suggestions
there too!!

Andrew

 

  <http://www.environcorp.com/> 

Andrew Sheaffer, PE, CPEnMS, CEM | Manager, Carbon and Energy

ENVIRON International Corporation

333 W. Wacker | Suite 2700 | Chicago, IL 60606
T: +1 312 288 3897 | F: +1 312 288 3801 | M: +1 312 731 7096

asheaffer at environcorp.com <mailto:asheaffer at environcorp.com>  

 

 

________________________________

This message contains information that may be confidential, privileged or otherwise protected by law from disclosure. It is intended for the exclusive use of the Addressee(s). Unless you are the addressee or authorized agent of the addressee, you may not review, copy, distribute or disclose to anyone the message or any information contained within. If you have received this message in error, please contact the sender by electronic reply to email at environcorp.com and immediately delete all copies of the message. 

-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/bldg-sim-onebuilding.org/attachments/20121128/b6cd8089/attachment-0002.htm>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: not available
Type: image/png
Size: 5833 bytes
Desc: image001.png
URL: <http://lists.onebuilding.org/pipermail/bldg-sim-onebuilding.org/attachments/20121128/b6cd8089/attachment-0002.png>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: not available
Type: image/jpeg
Size: 1845 bytes
Desc: image002.jpg
URL: <http://lists.onebuilding.org/pipermail/bldg-sim-onebuilding.org/attachments/20121128/b6cd8089/attachment-0002.jpeg>


More information about the Bldg-sim mailing list