[Equest-users] eQuest LEED Compliance Engine Errors

Edward Allen eallen at long.com
Thu Dec 2 11:27:04 PST 2010


Thanks Pasha, Larry,

I searched the archives form the last couple of months and found this solution.  So far so good...

Thanks Again,
Edward M. Allen, PE, CEM
LONG Energy Solutions
Technology for Better Buildings
775.657.9180 office  720.217.1356 mobile  775.657.9180 fax
eallen at long.com
        http://www.long.com<http://www.long.com/>

________________________________
From: Larry Yang [mailto:LYang at enermodal.com]
Sent: Thursday, December 02, 2010 12:24 PM
To: Edward Allen; equest-users at lists.onebuilding.org
Subject: RE: [Equest-users] eQuest LEED Compliance Engine Errors

Edward,
I had encountered the same error massage before. The only solution is so far to check if you have any unconditioned zones that need to be changed as conditioned no matter what they should be. After Equest generating your LEED reference building successfully, you can turn them back. If this is your problem the solution might work for you too.
Larry Yang
_______________________________
Larry (Lijun) Yang
Enermodal Engineering Ltd.
t: 519.743.8777 x271
f: 519.743.8778
e: lyang at enermodal.com<mailto:lyang at enermodal.com>



From: equest-users-bounces at lists.onebuilding.org [mailto:equest-users-bounces at lists.onebuilding.org] On Behalf Of Edward Allen
Sent: Wednesday, December 01, 2010 6:35 PM
To: equest-users at lists.onebuilding.org
Subject: [Equest-users] eQuest LEED Compliance Engine Errors

Hello All,

I'm trying to use the LEED compliance analysis engine to build a budget building based on proposed design previously input using the wizard.  The model as input runs through the normal simulation without error.  The compliance analysis returns the following error:

Assign zone to baseline floor system:  CRule: Eva() error posting symbolic (value t.48092e-297) result to BDL

This error is repeated fifteen times in the compliance analysis error window.

I'm running 3.64, and I know some compliance engine problems were fixed for this version.  Has anyone else encountered this problem and developed a solution?

Thanks,


Edward M. Allen, PE, CEM
LONG Energy Solutions
Technology for Better Buildings
775.657.9180 office  720.217.1356 mobile  775.657.9180 fax
eallen at long.com
        http://www.long.com<http://www.long.com/>

-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20101202/4b3cc463/attachment-0002.htm>