[Equest-users] VRF in eQuest

Carol Gardner cmg750 at gmail.com
Thu May 13 16:28:34 PDT 2010


Hi all,

It's my pleasure to share information. I might be able to get some curve fit
info, too, but you will need to absolutely know what you are doing to
implement it. It is for when you are calling VRF/VRVs air source heat pumps.
NOT FOR WATER SOURCE. I will forward when I get it. You will use it only if
you are able to do so with skill!

Peace out,
Carol

On Thu, May 13, 2010 at 11:47 AM, Pasha Korber-Gonzalez <
pasha.pkconsulting at gmail.com> wrote:

> Carol, this is awesome--thanks for your assistance as always and I'll check
> back with you and all to let you know how it worked out for my project.
>
> thanks again,
> Pasha  :)
>
> On Thu, May 13, 2010 at 10:01 AM, Carol Gardner <cmg750 at gmail.com> wrote:
>
>> Pasha,
>>
>> Here is the info you needed for your VRV project. I'll send it via this
>> email as others may need similar data:
>>
>> I have included some input data below for the units you requested.  I have
>> given you the data in EIR form as that is what gets put into Equest and I
>> figured it would save a step.
>>
>> Here is the data I would enter for the systems:
>>
>>
>> *Outside Units*
>>
>> PURY-P234TGMU-A
>>
>> Cooling EIR: .315 Heating EIR: .294
>>
>> PURY-P72TGMU-A
>>
>> Cooling EIR: .307 Heating EIR: .271
>>
>> PURY-P144TGMU-A
>>
>> Cooling EIR: .336 Heating EIR: .291
>>
>> PURY-P108TGMU-A
>>
>> Cooling EIR: .307 Heating EIR: .282
>>
>> *Inside Units*
>>
>> PKFY-08 - .14watts/cfm
>>
>> PKY-12 - .08watts/cfm
>>
>> PKY-15 - .08watts/cfm
>>
>> PKY-024 - .06 watts/cfm
>>
>> PKY-30 - .07 watts/cfm
>>
>> Let me know if this works for you or if you need additional info,
>>
>> Cheers,
>>
>> Carol
>>
>>
>>
>>
>>
>>
>>  On Mon, May 10, 2010 at 11:44 AM, Pasha Korber-Gonzalez <
>> pasha.pkconsulting at gmail.com> wrote:
>>
>>>  Can't be done explicitly in eQuest.   I searched the
>>> www.onebuilding.org archives for VRV and VRF to see what past
>>> discussions and advice has been put out there.  At this point this is the
>>> best suggestion I can give.  I'm trying to model one now for a LEED
>>> project--not a smooth process.
>>>
>>> pasha
>>>
>>>   On Mon, May 10, 2010 at 10:21 AM, Lopez, Phylroy <
>>> Phylroy.Lopez at stantec.com> wrote:
>>>
>>>>    Has anybody done a VRF system in eQuest? Or know of any resources
>>>> that would detail how to do this?
>>>>
>>>>
>>>>
>>>> I want to make sure I am not rebuilding the wheel here.
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>> *Phylroy Lopez B.Eng LEED A.P.*
>>>> Sustainable Building Specialist
>>>> Stantec
>>>>
>>>> 1100 - 111 Dunsmuir Street
>>>> Vancouver BC V6B 6A3
>>>> Ph: (604) 696-8337
>>>> Fx: (604) 696-8100
>>>>
>>>> *stantec*.com <http://www.stantec.com/>
>>>>
>>>>
>>>>
>>>> The content of this email is the confidential property of Stantec and
>>>> should not be copied, modified, retransmitted, or used for any purpose
>>>> except with Stantec's written authorization. If you are not the intended
>>>> recipient, please delete all copies and notify us immediately.
>>>>
>>>>
>>>>
>>>> ü Please consider the environment before printing this email.
>>>>
>>>>
>>>>
>>>> *From:* equest-users-bounces at lists.onebuilding.org [mailto:
>>>> equest-users-bounces at lists.onebuilding.org] *On Behalf Of *Rob Hudson
>>>> *Sent:* Thursday, May 06, 2010 1:16 PM
>>>>
>>>> *To:* equest-users at lists.onebuilding.org
>>>> *Subject:* [Equest-users] Reheat/preheat/heating help
>>>>
>>>>
>>>>
>>>> I have a constant volume VAV system with a preheat coil, no heating
>>>> coil, and reheat box at the terminal.  The preheat is steam and the reheat
>>>> is hot water.  I am looking for verification on the way i set this up in the
>>>> model.  I set the heating capacity to 0 on the system level and entered in a
>>>> preheat coil under the preheat/baseboard tab.  Also under the preheat tab, i
>>>> entered my capacity and leaving air temp (50deg).  On the coil cap/control
>>>> tab i have entered my zone entering max supply temp = 87 deg, thats the temp
>>>> i want the reheats to go up to.  Then under each separate VAV zone, i
>>>> entered the reheat capacity under the Maximum Heating Rate.
>>>>
>>>> Let me know if i confused anyone or need to send pictures or files.
>>>>
>>>> --
>>>> Rob Hudson
>>>>
>>>> _______________________________________________
>>>> Equest-users mailing list
>>>>
>>>> http://lists.onebuilding.org/listinfo.cgi/equest-users-onebuilding.org
>>>> To unsubscribe from this mailing list send  a blank message to
>>>> EQUEST-USERS-UNSUBSCRIBE at ONEBUILDING.ORG
>>>>
>>>>
>>>
>>> _______________________________________________
>>> Equest-users mailing list
>>>
>>> http://lists.onebuilding.org/listinfo.cgi/equest-users-onebuilding.org
>>> To unsubscribe from this mailing list send  a blank message to
>>> EQUEST-USERS-UNSUBSCRIBE at ONEBUILDING.ORG
>>>
>>>
>>
>>
>> --
>> Carol Gardner PE
>>
>
>


-- 
Carol Gardner PE
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20100513/b58fa745/attachment-0001.htm>


More information about the Equest-users mailing list