Rob,

 

It’s slower/more accurate to break it up and put it on the individual zones, assuming you’re using the standard “dummy zone” approach for the make up air unit.  If you put it  on the make up air unit, it will see the return air from the dummy zone rather than the “real” return air from the conditioned zones.  I am not (consistently) happy with the results, especially when the ERV is distributed among many zones, but my opinion is that it’s faster than parsing hourly reports and determining the savings with an exceptional calculation.

 

                                

                         DAKOTA KELLEY                                                              

                                Project Designer

 

                                Office:      214-744-6199

                                Cell:         214-280-3825

                                Fax:         214-744-0770 

                

http://www.teliospc.com <http://www.teliospc.com/>           3535 Travis St. Suite 115 

dakotak at teliospc.com <mailto:dakotak at teliospc.com>              Dallas, TX 75204 

 

| MEP ENGINEERING · ENERGY MODELING · LEED CONSULTATION · COMMISSIONING |                         

 

 

CONFIDENTIALITY NOTICE: This email is intended only for the use of the individual or entity to which it is addressed, 

And may contain information that is privileged, confidential and exempt from disclosure under applicable law. If you 

are not the intended recipient, please email the sender immediately, and delete this email from all computers.  Any 

distribution or other use is strictly prohibited.  Copyright © 2010 Telios Corporation.

 

 

 

 

From: Rob Hudson [mailto:rdh4176 at gmail.com] 
Sent: Tuesday, May 25, 2010 10:33 AM
To: equest-users at lists.onebuilding.org
Subject: [Equest-users] VRF & ENTHALPY WHEEL

 

hey,
So i am creating a VRF system using the methods from that powerpoint that people posted not too long ago.  i have all my zones and systems almost ready, and i was wondering if people think that it would be easier/more accurate to put the enthalpy wheel on the make up air unit or the individual heat pump zones? 

-- 
Rob Hudson

-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20100525/5d2e91f1/attachment-0002.htm>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: not available
Type: image/png
Size: 3170 bytes
Desc: image001.png
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20100525/5d2e91f1/attachment-0002.png>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: not available
Type: image/jpeg
Size: 2327 bytes
Desc: image003.jpg
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20100525/5d2e91f1/attachment-0002.jpeg>


More information about the Equest-users mailing list