[Equest-users] PV results

Dakota Kelley dakotak at teliospc.com
Fri Nov 5 12:19:14 PDT 2010


I think the PS-C report has what you’re looking for.  It should show whatever you named the inverter along with a negative kWh value, indicating the power was generated on-site.  Attached is an example from a project that had a geothermal loop and a PV array.  The inverter is the Xantrex PV-10208.  This is a great report to see how your well field and PV arrays are doing throughout the year.

 

Thanks,

 

                                 

DAKOTA KELLEY 

Project Designer | Energy Analyst

                          

                              Office: 214.744.6199                 

                              Cell: 214.280.3825

                              Fax: 214.744.0770    

 

http://www.teliospc.com <http://www.teliospc.com/>          3535 Travis St. Suite 115

dakotak at teliospc.com            Dallas, TX 75204                                                     

                                

| MEP ENGINEERING · ENERGY MODELING · LEED CONSULTATION · COMMISSIONING |

 

CONFIDENTIALITY NOTICE: This email is intended only for the use of the individual or entity to which it is addressed, 

And may contain information that is privileged, confidential and exempt from disclosure under applicable law. If you

are not the intended recipient, please email the sender immediately, and delete this email from all computers.  Any 

distribution or other use is strictly prohibited.  Copyright © 2009 Telios Corporation.

 

 

 

 

 

 

 

From: Nick Caton [mailto:ncaton at smithboucher.com] 
Sent: Friday, November 05, 2010 1:51 PM
To: Juan Antonio Lopez; equest-users at lists.onebuilding.org
Subject: Re: [Equest-users] PV results

 

I have.  

 

For PV studies I typically build the rest of the model first, save a separate copy, then define the PV equipment and compare the two sets of results for overall figures.

 

For a more detailed look at the modeled results, explore the variety of custom hourly report options under “photovoltaic module.”  

 

~Nick

 

 

 

NICK CATON, E.I.T.

PROJECT ENGINEER

25501 west valley parkway

olathe ks 66061

direct 913 344.0036

fax 913 345.0617

Check out our new web-site @ www.smithboucher.com 

 

From: equest-users-bounces at lists.onebuilding.org [mailto:equest-users-bounces at lists.onebuilding.org] On Behalf Of Juan Antonio Lopez
Sent: Friday, November 05, 2010 11:26 AM
To: equest-users at lists.onebuilding.org
Subject: [Equest-users] PV results

 

Has anyone started incorporating a photovoltaic electric generator into your models?  where do you view the effect of the electric generator on the overall electrical consumption? 

-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20101105/68943202/attachment-0002.htm>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: not available
Type: image/jpeg
Size: 1459 bytes
Desc: image001.jpg
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20101105/68943202/attachment-0002.jpeg>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: not available
Type: application/octet-stream
Size: 6666 bytes
Desc: image002.emz
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20101105/68943202/attachment-0004.obj>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: not available
Type: image/png
Size: 3502 bytes
Desc: image003.png
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20101105/68943202/attachment-0002.png>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: PS-C Report.pdf
Type: application/octet-stream
Size: 27100 bytes
Desc: PS-C Report.pdf
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20101105/68943202/attachment-0005.obj>


More information about the Equest-users mailing list