[Equest-users] Query regarding PDEC ( Passive cooling ) simulation in eQuest

Mansi Jayswal ar.mansi.jayswal at gmail.com
Wed Mar 7 23:39:54 PST 2012


Thank you all for your quick response and Information.

Is it possible that if i use PHDC software to design the PDEC system and
simulate the same building in eQuest ??  PHDC software can give me
the required size of the passive down draught evaporating cooling towers
for the building.


On Wed, Mar 7, 2012 at 9:37 PM, Design Builder USA <
jcrossett at designbuilderusa.com> wrote:

> You may wish to explore the free trial of Design Builder, as it has CFD,
> natural ventilation and evaporate cooling.
> Tho I am not sure if it can be used for your passive cooling requirement
> or not..
>
> Best of luck
>
> On Wed, Mar 7, 2012 at 6:53 AM, Dahlstrom, Aaron <ADahlstrom at in-posse.com>wrote:
>
>> Mansi – ****
>>
>> ** **
>>
>> We have done some schematic modeling of wind towers with Fluent, a CFD
>> package as noted.****
>>
>> Our climate didn’t justify evaporative pre-cooling.****
>>
>> ** **
>>
>> eQUEST has a natural ventilation module, which I have not fully dived
>> into. ****
>>
>> ** **
>>
>> I believe it requires inputs that would likely be validated by a CFD
>> model – for example, I don’t think eQUEST’s natural ventilation model
>> allows for evaporative pre-cooling as a temperature driver for natural air
>> exchange in a space.****
>>
>> As eQUEST models each zone as a fully mixed space, and has limited air
>> transfer between zones, you may also have trouble getting the thermal
>> stratification from eQUEST that would typically be needed to drive natural
>> ventilation in a PDEC.****
>>
>> ** **
>>
>> *Aaron Dahlstrom , PE, LEED® AP*****
>>
>> *In P**o**sse* – A subsidiary of *AKF*| 1500 Walnut Street, Suite 1414,
>> Philadelphia, PA 19102 ****
>>
>> d: 215-282-6753| m: 267-507-5470| In Posse: 215-282-6800| AKF:
>> 215-735-7290****
>>
>> e: ADahlstrom at in-posse.com | in posse web: www.in-posse.com | akf web:
>> www.akfgroup.com****
>>
>>  ****
>>
>>  ****
>>
>>  ****
>>
>> *From:* equest-users-bounces at lists.onebuilding.org [mailto:
>> equest-users-bounces at lists.onebuilding.org] *On Behalf Of *Sami, Vikram
>> *Sent:* Wednesday, March 07, 2012 8:53 AM
>> *To:* Mansi Jayswal; equest-users at lists.onebuilding.org
>> *Subject:* Re: [Equest-users] Query regarding PDEC ( Passive cooling )
>> simulation in eQuest****
>>
>> ** **
>>
>> Mansi,****
>>
>> ** **
>>
>> I doubt you can do this credibly in eQUEST. You really need a CFD type
>> package to be able to simulate this. . A word of caution – the effort to
>> develop the simulation for this is a master’s thesis in itself. ****
>>
>> ** **
>>
>> ** **
>>
>> ** **
>>
>> * *
>>
>> *Vikram Sami*, LEED AP BD+C****
>>
>> Sustainable Design Analyst****
>>
>> 1315 Peachtree St. NE, Atlanta, GA 30309****
>>
>> t: 404-443-7462    f: 404.892.5823       e: vikram.sami at perkinswill.com
>> www.perkinswill.com****
>>
>> *Perkins+Will.*  Ideas + buildings that honor the broader goals of
>> society****
>>
>> ** **
>>
>> ** **
>>
>> *From:* equest-users-bounces at lists.onebuilding.org
>> [mailto:equest-users-bounces at lists.onebuilding.org] *On Behalf Of *Mansi
>> Jayswal
>> *Sent:* Tuesday, March 06, 2012 11:25 PM
>> *To:* equest-users at lists.onebuilding.org
>> *Subject:* [Equest-users] Query regarding PDEC ( Passive cooling )
>> simulation in eQuest****
>>
>> ** **
>>
>> ** **
>>
>> Hello friends,****
>>
>> ** **
>>
>> My name is Mansi Jayswal. I am a final year student of Masters Programme
>> at CEPT University, India. By profession I am an architect. Currently I am
>> doing thesis on passive cooling technique (Passive down draught evaporative
>> cooling system- PDEC ). And try to identified that how much cooling load of
>> HVAC system can be replaced through this system.****
>>
>> ** **
>>
>> Now my query is that is it eQuest is capable to simulate such building
>> with wind tower or PHDC (PDEC ) system? If anybody knows please kindly
>> reply. I have very days left for final submission and I am stuck here.***
>> *
>>
>> ** **
>>
>> Thanks ****
>>
>> ** **
>>
>> -- ****
>>
>>
>> Regards,****
>>
>> Mansi Jayswal,****
>>
>> B.Arch I IGBC AP I M.Tech in Climate Change & Sustainable Development ***
>> *
>>
>> Faculty of Sustainable Environment & Climate Change,****
>>
>> Centre for Environmental Planning & Technology (CEPT) University****
>>
>> ** **
>>
>> This e-mail may contain information that is confidential, privileged or
>> otherwise protected from disclosure. If you are not an intended recipient
>> of this e-mail, do not duplicate or redistribute it by any means. Please
>> delete it and any attachments and notify the sender that you have received
>> it in error. Unintended recipients are prohibited from taking action on the
>> basis of information in this e-mail. E-mail messages may contain computer
>> viruses or other defects, may not be accurately replicated on other
>> systems, or may be intercepted, deleted or interfered without the knowledge
>> of the sender or the intended recipient. If you are not comfortable with
>> the risks associated with e-mail messages, you may decide not to use e-mail
>> to communicate with In Posse.
>>
>> _______________________________________________
>> Equest-users mailing list
>> http://lists.onebuilding.org/listinfo.cgi/equest-users-onebuilding.org
>> To unsubscribe from this mailing list send  a blank message to
>> EQUEST-USERS-UNSUBSCRIBE at ONEBUILDING.ORG
>>
>>
>
>
> --
> Jeremiah D. Crossett
> Energy Modeling Consultant
> 503-688-8951
> www.DesignBuilderUSA.com <http://www.DesignBuilder.com>
>
>
>
>
>
>


-- 

Regards,
Mansi Jayswal,
B.Arch I IGBC AP I M.Tech in Climate Change & Sustainable Development
Faculty of Sustainable Environment & Climate Change,
Centre for Environmental Planning & Technology (CEPT) University
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20120308/444c680d/attachment-0002.htm>


More information about the Equest-users mailing list