[Bldg-sim] RES: EnergyPlus IDFs, gbXML and Bentley/Autodesk

Arpan Bakshi arpanbakshi at gmail.com
Thu May 24 13:43:08 PDT 2012


Bentley does not provide a 30-day trial for AECOsim Energy Simulator?


Arpan Bakshi, LEED AP BD+C



On Thu, May 24, 2012 at 4:40 PM, <Dru.Crawley at bentley.com> wrote:

>  AECOsim Energy Simulator currently allows user to import HVAC systems
> from IDFs to start building their HVAC models. We will be implementing more
> importing capabilities over the next months.  Users have the option of
> starting with one of the 28 preconfigured HVAC systems in AES and modifying
> those to match their system configuration.  These preconfigured HVAC
> systems give users access to all the EnergyPlus inputs required for each
> system.  Users can also create their own systems and save them for future
> use.****
>
> ** **
>
> AES offers three means of creating geometry – Conceptual model (select
> building and space types, set overall building height, weather location, %
> glazing, number of stories, draw the outline, select zoning, and HVAC
> system); 2-D (import floor plans – DGN, DWG, DXF, define rooms); and gbXML
> (import 3-D model, attribute spaces).****
>
> ** **
>
> When Energy Simulator starts a simulation, it automatically creates a
> user-readable IDF in the project directory.****
>
> ** **
>
> ** **
>
> ** **
>
> *From:* bldg-sim-bounces at lists.onebuilding.org [mailto:
> bldg-sim-bounces at lists.onebuilding.org] *On Behalf Of *Leandro Meneguelli
> Biondo
> *Sent:* Thursday, May 24, 2012 4:27 PM
> *To:* Lopez, Phylroy; bldg-sim at lists.onebuilding.org
> *Subject:* [Bldg-sim] RES: EnergyPlus IDFs, gbXML and Bentley/Autodesk****
>
> ** **
>
> Ok, but it would make more sense if this capability was buit in on both
> softwares… specially on AECOsim that uses the EP engine… I surely would
> like to have all the energyplus power for “freedom” on object settings
> (specially HVAC and green energy) working in parallel to the better
> interface and automation offered by the simulation suites. Would that be
> fair?****
>
> ** **
>
> *Leandro M Biondo*
> Consultor de Eficiência Energética****
>
> Meteorologista
> Rua Álvaro Rodrigues, 182 - Cj. 153
> Brooklin - São Paulo - CEP 04582-000
> tel: (11) 2149 0300 Ram.352/cel: (11) 6436 3510
> *http://www.cte.com.br* ****
>
> ** **
>
> ** **
>
> ** **
>
> *Aviso Legal*
>
> Esta mensagem pode conter informações confidenciais e/ou privilegiadas. Se
> você não****
>
> for o destinatário ou a pessoa autorizada a receber esta mensagem, não
> deve usar, copiar****
>
> ou divulgar as informações nela contida ou tomar qualquer ação baseada
> nessas****
>
> informações. Este ambiente está sujeito a monitoramento.****
>
> ** **
>
> *De:* Lopez, Phylroy [mailto:Phylroy.Lopez at NRCan-RNCan.gc.ca<Phylroy.Lopez at NRCan-RNCan.gc.ca>]
>
> *Enviada em:* Thursday, May 24, 2012 15:26
> *Para:* Leandro Meneguelli Biondo; bldg-sim at lists.onebuilding.org
> *Assunto:* RE: [Bldg-sim] EnergyPlus IDFs, gbXML and Bentley/Autodesk****
>
> ** **
>
>  ****
>
> Openstudio I think has that capability. If not it is in the works. ****
>
> ** **
>  ------------------------------
>
> *From:* bldg-sim-bounces at lists.onebuilding.org
> [mailto:bldg-sim-bounces at lists.onebuilding.org] *On Behalf Of *Leandro
> Meneguelli Biondo
> *Sent:* May 24, 2012 14:22
> *To:* bldg-sim at lists.onebuilding.org
> *Subject:* [Bldg-sim] EnergyPlus IDFs, gbXML and Bentley/Autodesk****
>
> This is a simple question that I tought of on the gbXML webinar thinking
> it would be a basic routine on both Bentley´s AECOsim and Autodesk´s Vasari
> systems, but haven´s found an answer so far. That is:****
>
> ** **
>
> How can I import EnergyPlus (5, 6 and 7) idf files with all my current
> modeling information to the environments? From what I have seen there
> always is a way to start from a gbXML, but how do I go from a “idf” file to
> a gbXML or straight to AECO or Vasari?****
>
> ** **
>
> Also, how do I keep compatibility between my AECO / Vasari simulations and
> a EnergyPlus model?****
>
> ** **
>
> ** **
>
> ** **
>
> [image: Descrição: Descrição: Descrição: Descrição:
> cid:image001.png at 01CC81F3.24A80950]****
>
> *Leandro M Biondo*
> Energy Efficiency Consultant****
>
> Meteorologist
> Rua Álvaro Rodrigues, 182 - Cj. 153
> Brooklin - São Paulo - Brasil
> tel: (11) 2149 0300 cel: (11) 6436 3510
> *http://www.cte.com.br* ****
>
> ** **
>
> ** **
>
> _______________________________________________
> Bldg-sim mailing list
> http://lists.onebuilding.org/listinfo.cgi/bldg-sim-onebuilding.org
> To unsubscribe from this mailing list send  a blank message to
> BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG
>
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/bldg-sim-onebuilding.org/attachments/20120524/bbb15b17/attachment-0002.htm>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: not available
Type: image/png
Size: 3624 bytes
Desc: not available
URL: <http://lists.onebuilding.org/pipermail/bldg-sim-onebuilding.org/attachments/20120524/bbb15b17/attachment-0002.png>