[Bldg-sim] Modelling oil-fired systems with different COPs in Designbuilder (Simple HVAC)

John Aulbach jra_sac at yahoo.com
Tue Sep 11 10:05:08 PDT 2012


Please give us your .INP and .PD2 files. How you can run oil in a "simple" HVAC model is beyond me. You cannot be in the Wizard.

John R. Aulbach, PE, CEM
Senior Energy Engineer

________________________________
 
PartnerEnergy
2154 Torrance Blvd, Ste. 100, Torrance, CA 90501
W: 888-826-1216, X254| D: 310-765-7295 | F: 310-817-2745
www.ptrenergy.com| jaulbach at ptrenergy.com


________________________________
 From: "Gupta, Apeksha" <GuptaA at bre.co.uk>
To: "bldg-sim at lists.onebuilding.org" <bldg-sim at lists.onebuilding.org> 
Sent: Tuesday, September 11, 2012 6:34 AM
Subject: [Bldg-sim] Modelling oil-fired systems with different COPs in Designbuilder (Simple HVAC)
 

Hello All,
I’m trying to compare two oil boilers with different COPs. One is 55% efficient and the other 82% efficient. I’m using the Simple HVAC model, however the results for Zone heating (kWh) do not change for the two boilers. All other parameters of the building remain the same. One would expect the lower efficiency boiler to perform more leading to a higher energy consumption to a higher efficiency boiler. Has anyone come across this in simulations? Can’t understand what I am doing incorrectly.
 
Regards,
Apeksha
 
Apeksha Gupta MSc
Renewable Energy KTP Associate
BRE Wales & South West
Ethos, Kings Road,
Swansea- SA1 8AS
T+44 1792 630 109M+44 (0) 754 894 3314 EGuptaa at bre.co.uk   Wwww.bre.co.uk
MAP:http://tinyurl.com/brewales
 
________________________________
 
For Green 
Deal news, information and more details on becoming involved: visit 
the BRE Green Deal Website Here 


Follow BRE 
on Twitter: @BREwatford 

________________________________
 
Privileged and 
confidential information and/or copyright material may be contained in this 
e-mail. If you are not the intended addressee you may not copy or deliver it to 
anyone else or use it in any unauthorised manner. To do so is prohibited and may 
be unlawful. If you have received this e-mail by mistake, please advise the 
sender immediately by return e-mail and destroy all copies. Thank you. Building Research Establishment Ltd, Registered under number 3319324 in 
England and Wales. VAT Registration No GB 689 9499 27 www.bre.co.uk
BRE Global Limited, Registered 
under number 3548352 in England and Wales. www.breglobal.com
Building Research 
Establishment and BRE Global are subsidiaries of the BRE Trust.
BRE Trust is 
a company limited by guarantee, Registered under number 3282856 in England and 
Wales, and registered as a charity in England (no. 1092193) and in Scotland (no. 
SC039320). www.bretrust.org.uk
Registered Offices: 
Bucknalls Lane, Garston, Watford, Hertfordshire WD25 9XX - Travelling to BRE: 
see www.bre.co.uk/directions
________________________________
 
_______________________________________________
Bldg-sim mailing list
http://lists.onebuilding.org/listinfo.cgi/bldg-sim-onebuilding.org
To unsubscribe from this mailing list send  a blank message to BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/bldg-sim-onebuilding.org/attachments/20120911/e6531781/attachment-0002.htm>


More information about the Bldg-sim mailing list