BuildingSurface:Detailed,
SURFACE NORTH ZONE1, !- Name
Wall, !- Surface Type
Wall-S&N, !- Construction Name
ZONE 1, !- Zone Name
Outdoors, !- Outside Boundary Condition
, !- Outside Boundary Condition Object
SunExposed, !- Sun Exposure
WindExposed, !- Wind Exposure
autocalculate, !- View Factor to Ground
autocalculate, !- Number of Vertices

0, 2.1, 2.4,       !- Vertex 1 XYZ-coordinate {m}
0, 2.1, 0,          !- Vertex 2 XYZ-coordinate {m}
4.4, 2.1, 0,       !- Vertex 3 XYZ-coordinate {m}
4.4, 2.1, 2.4;    !- Vertex 4 XYZ-coordinate {m}


This wall is facing South.  Reverse the order as follows.
 

4.4, 2.1, 2.4,      !- Vertex 4 XYZ-coordinate {m} 
4.4, 2.1, 0,        !- Vertex 3 XYZ-coordinate {m}
0, 2.1, 0,           !- Vertex 2 XYZ-coordinate {m}
0, 2.1, 2.4;        !- Vertex 1 XYZ-coordinate {m}


GlobalGeometryRules,
UpperLeftCorner, !- Starting Vertex Position
Counterclockwise, !- Vertex Entry Direction
Relative; !- Coordinate System

 
 
 Dr. Li  

 

To: EnergyPlus_Support@xxxxxxxxxxxxxxx
From: mohammadkheradmand@xxxxxxxxx
Date: Wed, 7 Mar 2012 09:18:10 -0800
Subject: Re: [EnergyPlus_Support] error

 
Thanks Dr.Li,
But i correct it,again same problem .could you please see .idf file, and help me

regards


From: YuanLu Li <yli006@xxxxxxxxxxx>
To: EnergyPlus_Support <energyplus_support@xxxxxxxxxxxxxxx>
Sent: Wednesday, March 7, 2012 5:10 PM
Subject: RE: [EnergyPlus_Support] error

 

Simple.
 
The North window is facing North, and the base wall in the NorthZone1  is facing South.
 
The program knows, and the simulation is like to continue.
 
How to correct the problem would depend on what you used to entered them.
 
 Dr. Li  

 

To: EnergyPlus_Support@xxxxxxxxxxxxxxx
From: mohammadkheradmand@xxxxxxxxx
Date: Wed, 7 Mar 2012 08:55:50 -0800
Subject: [EnergyPlus_Support] error

 
I have this error : 

 ** Severe  ** GetSurfaceData: Outward facing angle [0.0] of subsurface="NORTH WINDOW" significantly different than
   **   ~~~   ** ..facing angle [180.0] of base surface=SURFACE NORTH ZONE1 Tilt=90.0


what does mean?  where is my mistake?
regards






__._,_.___


Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx

The primary EnergyPlus web site is found at:
http://www.energyplus.gov

The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/

Attachments are currently allowed but be mindful that not everyone has a high speed connection.  Limit attachments to small files.

EnergyPlus Documentation is searchable.  Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.




Your email settings: Individual Email|Traditional
Change settings via the Web (Yahoo! ID required)
Change settings via email: Switch delivery to Daily Digest | Switch to Fully Featured
Visit Your Group | Yahoo! Groups Terms of Use | Unsubscribe

__,_._,___