[EnergyPlus_Support] Hot-water supply temperature reset based on outdoor temperature
- To: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Subject: [EnergyPlus_Support] Hot-water supply temperature reset based on outdoor temperature
- From: "FrancescoP" <direzionecontraria@xxxxxxxx>
- Date: Wed, 08 Aug 2012 15:23:24 -0000
- Delivered-to: mailing list EnergyPlus_Support@xxxxxxxxxxxxxxx
- Delivery-date: Wed, 08 Aug 2012 09:23:28 -0600
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoogroups.com; s=lima; t=1344439407; bh=Pk3hfdy8He1pTZo9cx0BOU1EAoZ+3CmrFO8lybZkmL0=; h=Received:Received:X-Yahoo-Newman-Id:X-Sender:X-Apparently-To:X-Received:X-Received:X-Received:X-Received:X-Received:To:Message-ID:User-Agent:X-Mailer:X-Originating-IP:X-eGroups-Msg-Info:X-Yahoo-Post-IP:From:X-Yahoo-Profile:Sender:MIME-Version:Mailing-List:Delivered-To:List-Id:Precedence:List-Unsubscribe:Date:Subject:Reply-To:X-Yahoo-Newman-Property:Content-Type:Content-Transfer-Encoding; b=Gnar1u7mIbF6B9JiBn14CdKAoQSr5eBXRQq2ajkkwjNod3GStorDvtBTeFCXzk1H9wS8ZiwDeVdFa//y3jrRv3ERACkH+PQBqKj/10IEvxOuWZq7L4FyJ+UTnAY7y6Ll
- Domainkey-signature: a=rsa-sha1; q=dns; c=nofws; s=lima; d=yahoogroups.com; b=bNqliGEIjEGyLr9jNQqx4vxcOlRlpnbeoghfSi14IbJOXM7PBLlXOjZOsRbHqiYwgE0mcYDW7dKULb9g1bWStgUKGRPFDRNnNB62Hs2EtVCE8Jqef8FNdVZJTe3CwIGZ;
- Envelope-to: linda@xxxxxxxxxxxxxx
- List-id: <EnergyPlus_Support.yahoogroups.com>
- List-unsubscribe: <mailto:EnergyPlus_Support-unsubscribe@yahoogroups.com>
- Mailing-list: list EnergyPlus_Support@xxxxxxxxxxxxxxx; contact EnergyPlus_Support-owner@xxxxxxxxxxxxxxx
- Reply-to: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Sender: EnergyPlus_Support@xxxxxxxxxxxxxxx
- User-agent: eGroups-EW/0.82
In order to obtain the certification LEED I have to respect the indications of ASHRAE 90.1-2007.
Paragraph G3.1.3.4 states: "Hot-water supply temperature shall be reset based on outdoor dry-bulb temperature using the following schedule: 82°C at -7°C and below, 66°C at 10°C and above, and ramped linearly between 82°C and 66°C at temperatures between -7°C and 10°C".
I wonder how I could model such a reset in EnergyPlus. Could you help me, please?
Best Regards
------------------------------------
Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx
The primary EnergyPlus web site is found at:
http://www.energyplus.gov
The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/
Attachments are currently allowed but be mindful that not everyone has a high speed connection. Limit attachments to small files.
EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.
Yahoo! Groups Links
<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/EnergyPlus_Support/
<*> Your email settings:
Individual Email | Traditional
<*> To change settings online go to:
http://groups.yahoo.com/group/EnergyPlus_Support/join
(Yahoo! ID required)
<*> To change settings via email:
EnergyPlus_Support-digest@xxxxxxxxxxxxxxx
EnergyPlus_Support-fullfeatured@xxxxxxxxxxxxxxx
<*> To unsubscribe from this group, send an email to:
EnergyPlus_Support-unsubscribe@xxxxxxxxxxxxxxx
<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/