Hi,

I got the CE100.idf from others and it was the old version. I updated it to version 8.1 and ran it. but got  a severe error.

 

MATERIAL:Regular-R,
          INSULATION-EXT,   ! Material Name
          VerySmooth,   ! Roughness
        50.00       ,   ! Thermal Resistance {m2-K/W}
          0.9000    ,   ! Thermal Absorptance
          0.1000    ,   ! Solar Absorptance
          0.1000    ;   ! Visible Absorptance

 MATERIAL:Regular-R,
          INSULATION-INT,   ! Material Name
          VerySmooth,   ! Roughness
        50.00       ,   ! Thermal Resistance {m2-K/W}
          0.9000    ,   ! Thermal Absorptance
          0.6000    ,   ! Solar Absorptance
          0.6000    ;   ! Visible Absorptance


  CONSTRUCTION,
            LTWALL,     ! Construction Name
              ! Material layer names follow:
              INSULATION-EXT,
              INSULATION-INT;

 

The error message is

This building has no thermal mass which can cause an unstable solution.
   **   ~~~   ** Use Material object for all opaque material definitions except very light insulation layers.

 

In Case E100 the wall construction is conposed of only two insulation layers.

 

Who can give me some advice?

 

Thank you very much.



__._,_.___

Posted by: dingwenting@xxxxxxxxx


Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx

The primary EnergyPlus web site is found at:
http://www.energyplus.gov

The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/

Attachments are currently allowed but be mindful that not everyone has a high speed connection.  Limit attachments to small files.

EnergyPlus Documentation is searchable.  Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.




Visit Your Group
Yahoo! Groups
PrivacyUnsubscribeTerms of Use

__,_._,___