Thanks for your input. I found looking at the LS-K reports - in fact I did text file comparisons of the LS-K sections of the .SIM reports for the two files - helped to track down the inadvertent discrepancies in the equipment loads I'd assigned to the spaces. Those discrepancies, combined with the CHW loop process load (which was different in the two runs do to the plant efficiency differences) accounted for the different Misc. Equip. end use energy.

 

I couldn't find the .PDF file that Brian Fountain mentioned - is this because I'm not in the most current version of eQuest? (I'm running 3.60)

 

Thanks for the help.

 

Kind Regards,

 

Molly Curtz, P.E.

Mechanical Engineer

 

Arup

403 Columbia St., Suite 220

Seattle, WA 98104

direct: 206 493 2234

tel: 206 749 9674 ext. 25534

fax: 206 749 0665

molly.curtz at arup.com

www.arup.com

From: Sethi, Amarpreet [mailto:amarpreet.sethi at stantec.com] 
Sent: Sunday, December 20, 2009 9:28 PM
To: Molly Curtz
Cc: equest-users at lists.onebuilding.org
Subject: RE: [Equest-users] Misc Equip End Use Category

 

HI Molly,

 

Another place you may want to check is under the utilitties tab - under the electric meter tab - under direct loads.  Sometimes we enter information in the wizard and that becomes a part of this input.

 

Hope all is well at your end.

 

cheers

Amarpreet

 


Stantec

stantec.com <http://www.stantec.com/>  

 

The content of this email is the confidential property of Stantec and should not be copied, modified, retransmitted, or used for any purpose except with Stantec's written authorization. If you are not the intended recipient, please delete all copies and notify us immediately.

 

ü Please consider the environment before printing this email.

 

 

________________________________

From: Brian Fountain [mailto:bfountain at greensim.com] 
Sent: Saturday, December 19, 2009 10:41 PM
To: Molly Curtz
Cc: equest-users at lists.onebuilding.org
Subject: Re: [Equest-users] Misc Equip End Use Category

There is a description of end use categorizations included in the following .pdf file:

Help -> Tutorials & Reference -> Detailed Simulation Reports Summary.pdf

The last 3 pages list what energy is grouped into the energy end use categories.

Hope this helps.

Brian

Molly Curtz wrote: 

Hi All,

I am trying to determine the cause of a discrepancy between "Misc Equip" in a baseline and proposed model.

I've already done a text file comparison on the .INP files, but have not yet identified the cause.

Could someone please list any other various energy uses that could be included in this category (other than the equipment/plug loads)?

So far I've determined that process loads on the Chilled water loop are reported under Misc. Equip. - any other ideas of items to look for?

Thanks very much for any suggestions.

Kind Regards,

Molly Curtz, P.E.

Mechanical Engineer

Arup

403 Columbia St., Suite 220

Seattle, WA 98104

direct: 206 493 2234

tel: 206 749 9674 ext. 25534

fax: 206 749 0665

molly.curtz at arup.com

www.arup.com

____________________________________________________________
Electronic mail messages entering and leaving Arup  business
systems are scanned for acceptability of content and viruses
  


________________________________



 
_______________________________________________
Equest-users mailing list
http://lists.onebuilding.org/listinfo.cgi/equest-users-onebuilding.org
To unsubscribe from this mailing list send  a blank message to EQUEST-USERS-UNSUBSCRIBE at ONEBUILDING.ORG
  


________________________________



 
 
No virus found in this incoming message.
Checked by AVG - www.avg.com 
Version: 8.5.427 / Virus Database: 270.14.113/2573 - Release Date: 12/18/09 07:35:00
 
  

 

-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20091221/04271409/attachment-0002.htm>


More information about the Equest-users mailing list