Found this in the onebuilding.org archive for equest-users:****

** **

On 8/25/10 8:26 AM, Scott Criswell wrote:****

>* Here is a rundown on the "MAX DEF" (maximum # of components) that can*

>* be defined in the version of DOE-2.2 distributed w/ eQUEST version*

>* 3.63b, as well as one change that will be present in the upcoming*

>* release of v3.64.*

>* *

>*     DOE-2.2 version     47d    47h2*

>*     eQUEST version    3.63b    3.64*

>*     -------------------------------*

>*     COMMAND NAME        MAX     MAX*

>*                         DEF     DEF*

>*     -------------------------------*

>*     SCHEDULE           2048*

>*     WEEK-SCHEDULE      2048*

>*     DAY-SCHEDULE       4096*

>*     BUILDING-SHADE     1024*

>*     CONSTRUCTION       8192*

>*     GLASS-TYPE         1024*

>*     SPACE              4096*

>*     EXTERIOR-WALL      8192*

>*     WINDOW             8192*

>*     INTERIOR-WALL      8192   12288*

>*     UNDERGROUND-WALL   8192*

>*     DESIGN-DAY            2*

>*     LAYERS             8192*

>*     MATERIAL           8192*

>*     REPORT-BLOCK         64*

>*     HOURLY-REPORT        16*

>*     RUN-PERIOD           15*

>*     PARAMETER           500*

>*     DOOR               1024*

>*     WEIGHTING-FACTOR   4096*

>*     FIXED-SHADE        1024*

>*     HOLIDAYS              2*

>*     POLYGON           32768*

>*     FLOOR              1024*

>*     GLASS-TYPE-CODE     128*

>*     SYSTEM             2048*

>*     ZONE               4096*

>*     CURVE-FIT           512*

>*     PUMP               1280*

>*     CIRCULATION-LOOP   1280*

>*     CHILLER              30*

>*     BOILER               30*

>*     DW-HEATER          1280*

>*     HEAT-REJECTION       30*

>*     PV-MODULE            30*

>*     ELEC-GENERATOR       30*

>*     THERMAL-STORAGE      30*

>*     HEAT-EXCHANGER       30*

>*     EQUIP-CTRL           30*

>*     LOAD-MANAGEMENT      20*

>*     ELEC-METER          100*

>*     FUEL-METER           15*

>*     STEAM-METER          15*

>*     CHW-METER            15*

>*     GROUND-LOOP-HX       30*

>*     LUMINAIRE-TYPE       64*

>*     LIGHTING-SYSTEM      64*

>*     LAMP-TYPE            64*

>*     COMPONENT-COST      100*

>*     UTILITY-RATE         30*

>*     BLOCK-CHARGE        200*

>*     RATCHET             100*

>*     WINDOW-LAYER         32*

>**

On Tue, Mar 19, 2013 at 7:14 AM, Sambhav Tiwari <tiwari.sambhav at gmail.com>wrote:

> Hi All,
>           What is maximum limit of no of spaces in building and shell  in
> 3.64 version
>
>
> Thanks
> Sambhav
>
> _______________________________________________
> Equest-users mailing list
> http://lists.onebuilding.org/listinfo.cgi/equest-users-onebuilding.org
> To unsubscribe from this mailing list send  a blank message to
> EQUEST-USERS-UNSUBSCRIBE at ONEBUILDING.ORG
>
>


-- 


Javed Iqbal, LEED AP, CEA