Well I hope it works, as it was the plan. jEPlus reads the .dck file and finds all ASSIGN statements. It then searches the ASSIGNed files for search tags and replace them with actual values, before saving the files into the job folder. .bui should not be an exempt. Have you tried to put a search tag in the .bui file? If it doesn't work, you can send me your TRNSYS model...
Also, José Santiago Villar developed a method for linking EnergyPlus parametrics with TRNSYS parametrics. He is working on a tutorial right now. Maybe soon you can use an E+ building model instead of type56.
Cheers,
Yi
Dr Yi Zhang
IESD, De Montfort University, United Kingdom
________________________________
From: Avesani Stefano [mailto:stefano.avesani at eurac.edu]
Sent: Mon 06/08/2012 15:29
To: Yi Zhang
Cc: trnsys-users at cae.wisc.edu; jsantv at gmail.com
Subject: RE: [TRNSYS-users] jEPlus for TRNSYS parametrics
...and actually *.bui is called in the *.dck thanks to an ASSIGN statement.
Could therefore parametrical runs work?
Thanks a lot
Stefano
Stefano Avesani
Institute for Renewable Energy
EURAC research
Viale Druso 1, I-39100 Bolzano
t +39 0471 055 654
f +39 0471 055 699
stefano.avesani at eurac.edu <mailto:petra.muster at eurac.edu>
www.eurac.edu <http://www.eurac.edu/>
This transmission is intended only for the use of the addressee and may contain confidential or legally privileged information.
If you receive this transmission by error, please notify the author immediately by mail and delete all copies of this transmission and any attachments.
Any use or dissemination of this communication is strictly prohibited by the "Privacy-Code", D.Lgs. 196/2003 and may lead to penal prosecution and liability for damages.
P Think before you print
From: Yi Zhang [mailto:YiZhang at dmu.ac.uk]
Sent: Monday, 06 August, 2012 14:40
To: Avesani Stefano; saleh saadi; bjoern.nienborg at ise.fraunhofer.de
Cc: trnsys-users at cae.wisc.edu; jsantv at gmail.com
Subject: RE: [TRNSYS-users] jEPlus for TRNSYS parametrics
Dear Stefano/Saleh,
Sorry I don't recall if I responded to Saleh's earlier question or not... Since I am not a TRNSYS user, José can correct me if I get anything wrong.
jEPlus searches the specified search tags in the main .DCK or .TRD files, as well as in any external files loaded by an INCLUDE or an ASSIGN command. I don't know about the .BUI files; but if they are loaded in the main .DCK file, you should be able to have parameters in them. To edit a file other than the main .DCK, you will need to use a text editor...
To the second question, jEPlus processes output files in CSV format only. Your model needs to write output in a .csv using the right printer, and you tell jEPlus the files you want it to collect in the "output file name(s)" field (I am renaming it to "printer file name(s)"). So "trnsysout.csv" should be a printer name you have in your .DCK model.
We are still working on the TRNSYS part of the users manual. It should be ready in a few days' time.
Cheers,
Yi
Dr Yi Zhang
IESD, De Montfort University, United Kingdom
________________________________
From: Avesani Stefano [mailto:stefano.avesani at eurac.edu]
Sent: Mon 06/08/2012 13:02
To: saleh saadi; Yi Zhang; bjoern.nienborg at ise.fraunhofer.de
Cc: trnsys-users at cae.wisc.edu
Subject: RE: [TRNSYS-users] jEPlus for TRNSYS parametrics
Dear all,
Any news concerning the use of jeplus for parametric changes in the *.bui (and not just in the *.dck) of a trnsys project?
Thanks a lot
Best regards
Stefano
Stefano Avesani
Institute for Renewable Energy
EURAC research
Viale Druso 1, I-39100 Bolzano
t +39 0471 055 654
f +39 0471 055 699
stefano.avesani at eurac.edu <mailto:petra.muster at eurac.edu>
www.eurac.edu <http://www.eurac.edu/>
This transmission is intended only for the use of the addressee and may contain confidential or legally privileged information.
If you receive this transmission by error, please notify the author immediately by mail and delete all copies of this transmission and any attachments.
Any use or dissemination of this communication is strictly prohibited by the "Privacy-Code", D.Lgs. 196/2003 and may lead to penal prosecution and liability for damages.
P Think before you print
From: trnsys-users-bounces at cae.wisc.edu [mailto:trnsys-users-bounces at cae.wisc.edu] On Behalf Of saleh saadi
Sent: Monday, 07 May, 2012 19:59
To: Yi Zhang; bjoern.nienborg at ise.fraunhofer.de
Cc: trnsys-users at cae.wisc.edu
Subject: Re: [TRNSYS-users] jEPlus for TRNSYS parametrics
Dear Dr Zhang,
Thanks for doing this great job!!!.
I used the template file provided with GenOpt (folder is attached).
I tried using this version with TRNSYS 16 and works pretty well and quick (24 parametric runs in less than a minute). Is it possible to add a browsing tab to edit the building file (*.bui).
Although, I could run the parametric files but no output was extracted. In my template file, I normally extract output in a text file but jEPlus could not copy the file or save it in any format. Is there a way to save the text file in the folder file similar to input file. In addition, I can't find the "trnsysout.csv" output file anywhere. Is that enabled in this version?
regards,
saleh alsaadi
________________________________
From: Yi Zhang <YiZhang at dmu.ac.uk>
To: bjoern.nienborg at ise.fraunhofer.de
Cc: trnsys-users at cae.wisc.edu
Sent: Monday, May 7, 2012 7:58 AM
Subject: Re: [TRNSYS-users] jEPlus for TRNSYS parametrics
Hi Bjoern,
I should provide an example TRNSYS parametric project in the package; I will do that in a couple of days. In the meantime, could you take a look at the E+ example? Just open the project in the example/ folder, and you will see how to specify parameters. Unlike E+, the weather file in a TRNSYS model is normal parameter. You just need to create a parameter and think of a search string (e.g. "@@weather@@") to put in the place of the weather file in the .DCK (or .TRD) file, and then specify the alt. values of the parameter using syntax like "{weather1.txt, weather2.txt, ...}".
Here is quick video of how to use jEPlus (http://www.youtube.com/watch?feature=player_embedded&v=9v8k52IyvV4). Again it is for E+ rather than TRNSYS; but the principle is the same.
Cheers,
Yi
Dr Yi Zhang
IESD, De Montfort University, United Kingdom
________________________________
From: Bjoern Nienborg [mailto:bjoern.nienborg at ise.fraunhofer.de]
Sent: Mon 07/05/2012 14:30
To: Yi Zhang
Subject: Re: [TRNSYS-users] jEPlus for TRNSYS parametrics
Hi Yi,
I just had a short look at it and did not find an option to vary sets of values, e.g. if I vary a location I need to specify the name of the weather data file, the latitude, shift in solar time and possibly some other values. If there is this option and I did not see it, please ignore my comment.
Regards,
björn
Am 07.05.2012 13:43, schrieb Yi Zhang:
Hi all,
jEPlus is an open source parametric tool for managing EnergyPlus simulations. Due to popular demand, support for TRNSYS simulations has been added to the latest version (jEPlus v1.3beta). Please visit http://www.iesd.dmu.ac.uk/jeplus/ for more details. Please note we are currently testing the new version; any comments or suggestions will be much appreciated.
Regards,
Yi
Dr Yi Zhang
IESD, De Montfort University, United Kingdom
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users at cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users
--
Dipl.-Ing. (FH) Björn Nienborg, M.Sc.
Division Thermal Systems and Buildings
Fraunhofer Institut für Solare Energiesysteme ISE
Heidenhofstr. 2, 79110 Freiburg, Germany
Tel.: +49 (0)761 4588-5883 FAX: +49 (0)761 4588-9000
http://www.ise.fraunhofer.de/
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users at cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/trnsys-users-onebuilding.org/attachments/20120806/792e5354/attachment-0001.htm>
More information about the TRNSYS-users
mailing list