[TRNSYS-users] Glazing of windows' u-and g-value

Moises Odriozola Maritorena moises.odriozola at ehu.es
Thu Aug 30 02:52:11 PDT 2012


Hi Wang,

I define my windows with the software Window (from Lawrence Berkeley  
National Laboratory). It is free and very easy to use.

Best regards,

Moises Odriozola.

王洋 <wanghongyang1767 at gmail.com> escribió:

> Dear all,
>
> I tried to create some new windows types based on my real building windows'
> data in TRNBuild. But I found I can't change glazing-u-and g-values, I must
> refer to glazing library Window Type manager said. However, I can't find
> the exactly identical u-(0.60) and g-value (0.52) for my windows type. Who
> could have some experiences for that, Please tell me in detail how to find
> or define the exactly identical u-(0.60) and g-value (0.52) for my windows
> type in TRNBuild?
>
> Many thanks in advance!
> Br.
> wang
>
> 2012/8/28 <trnsys-users-request at cae.wisc.edu>
>
>> Send TRNSYS-users mailing list submissions to
>>         trnsys-users at cae.wisc.edu
>>
>> To subscribe or unsubscribe via the World Wide Web, visit
>>         https://mailman.cae.wisc.edu/listinfo/trnsys-users
>> or, via email, send a message with subject or body 'help' to
>>         trnsys-users-request at cae.wisc.edu
>>
>> You can reach the person managing the list at
>>         trnsys-users-owner at cae.wisc.edu
>>
>> When replying, please edit your Subject line so it is more specific
>> than "Re: Contents of TRNSYS-users digest..."
>>
>> Today's Topics:
>>
>>    1. Ground properties (??????? ???????????)
>>    2. Internal energy variation (??????? ???????????)
>>    3. Results (??????? ???????????)
>>
>>
>> ---------- 已转发邮件 ----------
>> From: "Айгерим Сейдуалиева" <i.gera at mail.ru>
>> To: trnsys-users-request <trnsys-users-request at cae.wisc.edu>,
>> trnsys-users <trnsys-users at cae.wisc.edu>
>> Cc:
>> Date: Tue, 28 Aug 2012 23:06:13 +0400
>> Subject: [TRNSYS-users] Ground properties
>> Dear all,
>>
>> I am doing the GSHPs. Could you tell me how can I test the different types
>> of soil in TRNSYS? Should I change thermal conductivity and volumetrric
>> heat capacity of the heat loop?
>>
>> Thanks
>> Aigerim
>>
>>
>> ---------- 已转发邮件 ----------
>> From: "Айгерим Сейдуалиева" <i.gera at mail.ru>
>> To: trnsys-users-request <trnsys-users-request at cae.wisc.edu>,
>> trnsys-users <trnsys-users at cae.wisc.edu>
>> Cc:
>> Date: Tue, 28 Aug 2012 23:45:17 +0400
>> Subject: [TRNSYS-users] Internal energy variation
>>
>> Dear all,
>>
>> I am calculating heat pumps. And Could u tell me what shows internal
>> energy variation?
>>
>> Thanks
>> Aika
>>
>>
>> ---------- 已转发邮件 ----------
>> From: "Айгерим Сейдуалиева" <i.gera at mail.ru>
>> To: trnsys-users-request <trnsys-users-request at cae.wisc.edu>,
>> trnsys-users <trnsys-users at cae.wisc.edu>
>> Cc:
>> Date: Wed, 29 Aug 2012 00:16:15 +0400
>> Subject: [TRNSYS-users] Results
>> Dear all,
>>
>> I got results of Existing fluid temperature and internal energy variation.
>> But I am confusing with the numbers I got. Can you explain how to manage
>> it? Or is it right numbers?
>>
>> Thanks
>> Aika
>>
>>
>>
>>
>> _______________________________________________
>> TRNSYS-users mailing list
>> TRNSYS-users at cae.wisc.edu
>> https://mailman.cae.wisc.edu/listinfo/trnsys-users
>>
>>
>







More information about the TRNSYS-users mailing list