[TRNSYS-users] TRNSYS Genopt

Yi Zhang YiZhang at dmu.ac.uk
Wed Oct 9 06:21:04 PDT 2013


Try find a way to put this part: C:\Program Files (x86)\Trnsys17_1\Exe\TRNEXE.EXE into a pair of quote marks should solve the problem. Unfortunately I am not a TRNOPT user, so not be able to tell you how. In GenOpt though, the line is in one of the configure files...

Yi

From: trnsys-users-bounces at cae.wisc.edu [mailto:trnsys-users-bounces at cae.wisc.edu] On Behalf Of Julian Buderus
Sent: 09 October 2013 12:44
To: trnsys-users at cae.wisc.edu
Subject: [TRNSYS-users] TRNSYS Genopt

Dear trnsys-users,

I'm trying to use TRNSYS and GenOpt. In TRNSYS is a small example for using TRNOPT / GenOpt. When trying to optimize this
example GenOpt gives me an error message like this:

Assigning 8 threads for simulations.
Initialize.
java.lang.Exception:

Exception in executing the simulation program

Simulation working directory : 'C:\Program Files (x86)\Trnsys17_1\Optimization\GenOpt\Simulation\tmp-genopt-run-1'
Command string               : 'C:\Program Files (x86)\Trnsys17_1\Exe\TRNEXE.EXE "C:\Program Files (x86)\Trnsys17_1\Optimization\GenOpt\Simulation\tmp-genopt-run-1\GenoptInputFile.DCK" /n /WAIT '
Exception message:
Cannot run program "C:\Program" (in directory "C:\Program Files (x86)\Trnsys17_1\Optimization\GenOpt\Simulation\tmp-genopt-run-1"): CreateProcess error=2, Das System kann die angegebene Datei nicht finden

GenOpt terminated with error.
See logfile for further information.

Can somebody tell me what I am doing wrong?

Kind regards,

Julian Buderus
Forschungsgebiet Gebäudesysteme
Institut für Energie und Gebäude (ieg)
Technische Hochschule Nürnberg Georg Simon Ohm
Postfach, 90121 Nürnberg

Besucheradresse:
K:  STANDORT KESSLERPLATZ<http://www.th-nuernberg.de/seitenbaum/home/lageplan/k-standort-kesslerplatz/page.html>
Keßlerplatz 12, 90489 Nürnberg
Gebäude KH, Raum KH.118

Telefon:  +49 911/5880-1830
Telefax:  +49 911/5880-5846
E-Mail: julian.buderus at th-nuernberg.de<mailto:julian.buderus at th-nuernberg.de>
www.ieg.th-nuernberg.de<http://www.th-nuernberg.de/>