[Bldg-sim] ASHRAE 55-2004 Thermal Comfort Spreadsheet
Min Yan
building0729 at gmail.com
Fri Jun 11 15:22:40 PDT 2010
There are some equations to calculate them. The psychrometric chart does not
help lot. I used to calculate PMV/PPD with my own VB 6. But there are a few
important PMV/PPD equations behind the VB6.0 from some references that I
forgot.
There is nothing to do with climate consultants, BTW.
On Fri, Jun 11, 2010 at 12:46 PM, Mary Wyllie <MWyllie at hiscutt-aia.com>wrote:
> I uploaded a Psychrometric Chart that I created using a free program
> called Climate Consultant.
>
>
>
> *Mary Wyllie | **AIA **|** **LEED AP*
>
> Associate
>
> Hiscutt & Associates, Inc.
>
> 3655 Brookside Pkwy., Suite 575
>
> Alpharetta, GA 30022
>
> (770) 753-8787
>
>
>
> *R**educe **R**euse **R**ecycle **ü*
> ------------------------------
>
> *From:* bldg-sim-bounces at lists.onebuilding.org [mailto:
> bldg-sim-bounces at lists.onebuilding.org] *On Behalf Of *Jason Wendel
> *Sent:* Friday, June 11, 2010 12:34 PM
> *To:* 'Bridgette Baugher'; 'bldg-sim at lists.onebuilding.org'
> *Subject:* Re: [Bldg-sim] ASHRAE 55-2004 Thermal Comfort Spreadsheet
>
>
>
> For LEED 3.0 (2009) the wording is “Upload supporting documentation with
> PMV/PPD calculation, ASHRAE comfort tool results, and/or psychrometric
> comfort zone chart from Standard 55”
>
> For LEED 2.2 you just had to provide a narrative, but 3.0 requires the
> actual results from the calculations. I may just have to buy ASHRAE’s
> “Thermal Comfort Tool”, I was just hoping there was something else
> available.
>
>
>
> -Jason
>
>
>
> *From:* Bridgette Baugher [mailto:BBaugher at southlandind.com]
> *Sent:* Friday, June 11, 2010 10:29 AM
> *To:* Jason Wendel
> *Subject:* RE: [Bldg-sim] ASHRAE 55-2004 Thermal Comfort Spreadsheet
>
>
>
> I would be interested to see if anyone has actually done a calculation for
> this. It’s been a while since submitting this credit, but if I remember
> correctly, the only requirement from LEED was a narrative from the engineer.
>
>
>
> BRIDGETTE BAUGHER
>
> EIT, LEED AP
>
>
>
> Energy Engineer
>
> Southland Industries
>
> 22340 Dresden Street, Suite 177
>
> Dulles, VA 20166
>
> Office: 703.834.5570
>
> Direct: 703.834.2426
>
> Fax: 703.834.5572
>
>
>
> *From:* Jason Wendel [mailto:jwendel at heatheng.com]
> *Sent:* Friday, June 11, 2010 12:23 PM
> *To:* Bridgette Baugher
> *Subject:* RE: [Bldg-sim] ASHRAE 55-2004 Thermal Comfort Spreadsheet
>
>
>
> IEQc7.2 is a survey of the occupants, but IEQc7.1 – Thermal Comfort –
> Design requires complying with ASHRAE 55.
>
>
>
> -Jason
>
>
>
> *From:* Bridgette Baugher [mailto:BBaugher at southlandind.com]
> *Sent:* Friday, June 11, 2010 10:20 AM
> *To:* Jason Wendel
> *Subject:* RE: [Bldg-sim] ASHRAE 55-2004 Thermal Comfort Spreadsheet
>
>
>
> How would you calculate this? I thought it was a survey of the occupants.
>
>
>
> BRIDGETTE BAUGHER
>
> EIT, LEED AP
>
>
>
> Energy Engineer
>
> Southland Industries
>
> 22340 Dresden Street, Suite 177
>
> Dulles, VA 20166
>
> Office: 703.834.5570
>
> Direct: 703.834.2426
>
> Fax: 703.834.5572
>
>
>
> *From:* bldg-sim-bounces at lists.onebuilding.org [mailto:
> bldg-sim-bounces at lists.onebuilding.org] *On Behalf Of *Jason Wendel
> *Sent:* Friday, June 11, 2010 12:04 PM
> *To:* 'bldg-sim at lists.onebuilding.org'
> *Subject:* [Bldg-sim] ASHRAE 55-2004 Thermal Comfort Spreadsheet
>
>
>
> Does anyone have a spreadsheet to calculate PMV-PPD for ASHRAE 55-2004?
>
>
>
> -Jason
>
>
>
> _______________________________________________
> Bldg-sim mailing list
> http://lists.onebuilding.org/listinfo.cgi/bldg-sim-onebuilding.org
> To unsubscribe from this mailing list send a blank message to
> BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG
>
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/bldg-sim-onebuilding.org/attachments/20100611/8916909e/attachment-0001.htm>
More information about the Bldg-sim
mailing list