[Bldg-sim] Comfort tools

Tariq Abbas tabbas at hilsonmoran.com
Wed Jan 26 06:14:19 PST 2011


I don't think it can predict in zone gradients of TC. 
TARIQ ABBAS BEng, MSc, LEED AP 

HEAD OF SUSTAINABILITY - UAE 

Tel : +971 2 677 4220 
Fax : +971 2 677 4202 
Mobile : +971 50 8213327 
Email : tabbas at hilsonmoran.com 
Web : www.hilsonmoran.com 
Registered no: 1233447 England. Registered office : 16 Armstrong Mall, Southwood, Farnborough Hampshire, GU14 0NR 

"This message is for the named person's use only. It may contain confidential, proprietary or legally privileged information. No confidentiality or priviledge is waived or lost by erroneous transmission. If you receive this message in error, please immediately delete it and all copies of it from your system, destroy and hard copies of it and notify the sender. You must not, directly or indirectly, use, disclose, distribute, print, or copy any part of this message if you are not the intended recipient. Hilson Moran Partnership Ltd reserves the right to monitor all E-Mail communications through its networks. Any view expressed in this message is those of the sender, except where the message specifically states them to be the views of Hilson Moran Partnership Ltd. All transmissions are checked for viruses but all recipients are advised to undertake their own virus checks as Hilson Moran Partnership Ltd will not take responsibility for any damages arising from virus infections".

________________________________

From: Julia Beabout <juliabeabout at yahoo.com> 
To: Tariq Abbas; Patrick J. O'Leary, Jr. <poleary1969 at gmail.com>; Arpan Bakshi <arpanbakshi at gmail.com> 
Cc: bldg-sim at lists.onebuilding.org <bldg-sim at lists.onebuilding.org> 
Sent: Wed Jan 26 13:51:55 2011
Subject: Re: [Bldg-sim] Comfort tools 


I've heard that TAS can do this.  


________________________________

From: Tariq Abbas <tabbas at hilsonmoran.com>
To: "Patrick J. O'Leary, Jr." <poleary1969 at gmail.com>; Arpan Bakshi <arpanbakshi at gmail.com>
Cc: bldg-sim at lists.onebuilding.org
Sent: Wed, January 26, 2011 8:18:53 AM
Subject: Re: [Bldg-sim] Comfort tools



Sounds impossible.

 

Information in bulk zone modelling is only stored at the node (typically centre of zone) and on surfaces with no additional info in between. 

 

There are too many unknown parameters to determine thermal comfort in this way to determine a gradient. 

 

You would have to use CFD which can be tricky without experience of solar radiation modelling (depending on package used).

 

 

 

From: bldg-sim-bounces at lists.onebuilding.org [mailto:bldg-sim-bounces at lists.onebuilding.org] On Behalf Of Patrick J. O'Leary, Jr.
Sent: 26 January 2011 02:53
To: Arpan Bakshi
Cc: bldg-sim at lists.onebuilding.org
Subject: Re: [Bldg-sim] Comfort tools

 

attached is a screenshot of the ashrae comfort tool output



On 1/24/11 10:06 AM, Arpan Bakshi wrote: 

Comfort Gradients

 

Are there other tools out there which are specifically developed to perform only comfort calculations, PMV, PPD, etc.?

 

My understanding of the comfort models in DesignBuilder, ApacheSim other energy modeling engines is that they calculate comfort only at the central node of each thermal zone. 

 

Is anyone aware of tools which calculate a gradient of comfort within each thermal zone?

 

 

Thanks

Arpan

 

  
  
_______________________________________________
Bldg-sim mailing list
http://lists.onebuilding.org/listinfo.cgi/bldg-sim-onebuilding.org
To
 unsubscribe from this mailing list send  a blank message to BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG
  



______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/bldg-sim-onebuilding.org/attachments/20110126/21c9affd/attachment-0002.htm>


More information about the Bldg-sim mailing list