Shaun,

I don't use eQUEST, but I have converted DOE-2.2 input files to 
DOE-2.1E, and have never seen any problems with the building geometry 
once the correct transpositions have been done with the multiple 
coordinate systems.

How did you input the floor polygon? Could that be the cause for this 
discrepancy?  What is the actual azimuth for
the wall in the global coordinate system, anyway?

Joe


On 7/8/2014 9:41 PM, Shaun Martin wrote:
>
> Hi Joe,
>
> I think it's just an internal error in equest.  My building, floor, 
> and space are all exactly north-south.  The only thing that is off 
> slightly are the coordinates of the space polygon, which gives me the 
> 91.27 deg angle.  Something for version 3.66, I guess.
>
> Shaun
>
> *From:*Bldg-sim [mailto:bldg-sim-bounces at lists.onebuilding.org] *On 
> Behalf Of *Joe Huang
> *Sent:* Tuesday, July 08, 2014 5:25 PM
> *To:* bldg-sim at lists.onebuilding.org
> *Subject:* Re: [Bldg-sim] Azimuth in equest
>
> In eQUEST, there's a further nesting of the coordinates at the FLOOR 
> level, i.e.,
>     Building -> Floor -> Space
> The FLOOR coordinates are particularly important, since the floor 
> footprint (POLYGON = XXX, SHAPE = POLYGON) defines the origin and 
> azimuth for the walls.
>
> Joe
>
> Joe Huang
> White Box Technologies, Inc.
> 346 Rheem Blvd., Suite 108D
> Moraga CA 94556
> yjhuang at whiteboxtechnologies.com  <mailto:yjhuang at whiteboxtechnologies.com>
> http://weather.whiteboxtechnologies.com  for simulation-ready weather data
> (o) (925)388-0265
> (c) (510)928-2683
> "building energy simulations at your fingertips"
>
>
> On 7/8/2014 3:10 PM, Jeff Haberl wrote:
>
>  Shaun,
>
> Also, within DOE-2 simulations there are (3) orientations: the 
> building, the space and the exterior/interior surface. Hence, you can 
> easily have a -91.27 = northeast if you don't know all (3) 
> orientations. You can see this in the LV- or verification reports for 
> LOADS. You should be able to see this in the "viewer" as well (of 
> which there are several).
>
> Jeff
>
> 8=!  8=)  :=)  8=)  ;=)  8=) 8=(  8=)  8=()  8=)  8=|  8=)  :=')  8=) 8=?
> Jeff S. Haberl, 
> Ph.D.,P.E.inactive,FASHRAE,FIBPSA,......jhaberl at tamu.edu 
> <mailto:........jhaberl at tamu.edu>
> Professor........................................................................Office 
> Ph: 979-845-6507
> Department of 
> Architecture............................................Lab 
> Ph:979-845-6065
> Energy Systems 
> Laboratory...........................................FAX: 979-862-2457
> Texas A&M 
> University...................................................77843-3581
> College Station, Texas, USA, 
> 77843..............................URL:www.esl.tamu.edu
> 8=/  8=)  :=)  8=)  ;=)  8=)  8=()  8=)  :=)  8=) 8=!  8=)  8=? 8=) 8=0
>
> ------------------------------------------------------------------------
>
> *From:*Bldg-sim [bldg-sim-bounces at lists.onebuilding.org 
> <mailto:bldg-sim-bounces at lists.onebuilding.org>] on behalf of John 
> Aulbach [jra_sac at yahoo.com <mailto:jra_sac at yahoo.com>]
> *Sent:* Tuesday, July 08, 2014 4:53 PM
> *To:* Shaun Martin; bldg-sim at lists.onebuilding.org 
> <mailto:bldg-sim at lists.onebuilding.org>
> *Subject:* Re: [Bldg-sim] Azimuth in equest
>
> I am going to guess your Ploygon is part of a larger building. When 
> you say you set the Azimuth of the Polygon, what is the Azimuth of the 
> Building itself?
>
> John R. Aulbach, PE
>
> On Tuesday, July 8, 2014 10:41 AM, Shaun Martin 
> <smartin at shaunmartinconsulting.com> 
> <mailto:smartin at shaunmartinconsulting.com> wrote:
>
> In equest, SHAPE = POLYGON  determines the x, y, z, azimuth.  Does 
> anybody happen know why a wall with an azimuth of -91.27^deg would be 
> listed as NORTH-EAST in the LV-D report?  Is there any easy way to fix 
> this without redoing all the polygons?  (Specifying the AZIMUTH does 
> not work.)
>
> Thanks,
>
> /Shaun Martin LEED AP/
>
> /Principal/
>
> /Shaun Martin Consulting/
>
> /2060 Pine Street/
>
> /Vancouver, BC V6J 4P8/
>
> /P: 604-789-1095/
>
> /E: smartin at shaunmartinconsulting.com 
> <mailto:smartin at shaunmartinconsulting.com>/
>
>
> _______________________________________________
> Bldg-sim mailing list
> http://lists.onebuilding.org/listinfo.cgi/bldg-sim-onebuilding.org
> To unsubscribe from this mailing list send a blank message to 
> BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG 
> <mailto:BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG>
>
>   
>   
> _______________________________________________
> Bldg-sim mailing list
> http://lists.onebuilding.org/listinfo.cgi/bldg-sim-onebuilding.org
> To unsubscribe from this mailing list send  a blank message toBLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG  <mailto:BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG>

-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/bldg-sim-onebuilding.org/attachments/20140708/c9562c3f/attachment.htm>


More information about the Bldg-sim mailing list