[Bldg-sim] radiation through glazing

Chris Yates chris.malcolm.yates at gmail.com
Tue Mar 4 08:02:15 PST 2014


An ex boss lived in a Passivhaus and he couldn't get signal in the middle
of London.

A triple glazed unit can be quite thick. There were also multiple layers of
foil faced insulation in the walls. The Passivhaus institut may have done
some research on this.

Sent from my Android device. Please excuse typos, etc.
On 4 Mar 2014 15:26, <ldegelman at suddenlink.net> wrote:

> I don't see how there could be any effect at all.  The wavelengths are
> totally incompatible.  Low-e coatings block the near-infrared radiation at
> wavelengths of 700 to 2400 nanometers.  Even at the ultraviolet end, the
> wavelengths are around 100 to 400 nanometers.  The 3G and 4G networks that
> cell phones use are way off from this.  Typically, cell phone wavelengths
> (at 0.8 to 2.4 Ghz, the RF portion of the spectrum) are about one foot long
> (or around 300 million nanometers) - not even in the same ball park.
>
> \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
> Larry O. Degelman, PE, FIBPSA, ASHRAE
> Professor Emeritus of Architecture
> Texas A&M University
> //////////////////////////////////////////////////////////////
> -----Original Message----- From: Russell Richman
> Sent: Monday, March 03, 2014 10:00 PM
> To: leen peeters
> Cc: BldgSim Mailing List
> Subject: Re: [Bldg-sim] radiation through glazing
>
> these types of glazing systems will help reduce EMF's from the exterior.
>  As such, they 'may' reduce cell phone wave lengths as well.  I have not
> come across any studies, but the physics says it is possible.
> -russell
>
> On 2014-03-03, at 6:47 PM, leen peeters wrote:
>
>  Dear all,
>>
>> is there anyone aware of a negative impact of triple glazing or foils
>> used in triple glazing on the transmittance of mobile phone signals?
>>
>>
>> Any input is welcome ...
>>
>> leen
>> _______________________________________________
>> Bldg-sim mailing list
>> http://lists.onebuilding.org/listinfo.cgi/bldg-sim-onebuilding.org
>> To unsubscribe from this mailing list send  a blank message to
>> BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG
>>
>
> _______________________________________________
> Bldg-sim mailing list
> http://lists.onebuilding.org/listinfo.cgi/bldg-sim-onebuilding.org
> To unsubscribe from this mailing list send  a blank message to
> BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG
> _______________________________________________
> Bldg-sim mailing list
> http://lists.onebuilding.org/listinfo.cgi/bldg-sim-onebuilding.org
> To unsubscribe from this mailing list send  a blank message to
> BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/bldg-sim-onebuilding.org/attachments/20140304/3e4503b8/attachment-0002.htm>


More information about the Bldg-sim mailing list