[Bldg-sim] The solution to manufacturing process load for LEED energy simulation

Rathna Shree rathnashreep at yahoo.in
Thu Mar 26 02:41:16 PDT 2015


There are a couple of CIR's (ID# 10291 and #10237) which you can refer to address manufacturing facilities.  
 


     On Thursday, 26 March 2015 2:43 PM, 冷面寒枪 <503271081 at qq.com> wrote:
   

 Dear everyone,I have found a opinion about the the soultion to manufacturing process load for LEED energy simulation in internet,but I can not confirm if it is correct,does anyone can help me to confirm that or present some different opinions? The solution is shown as following: The biggest challenge you will face is in getting reduction for energy savings, as the process energy for your factory also has to be included in the calculation. In some factory projects the process energy itself can go up to 85 - 90% of the total energy. Getting a reduction like 12 - 15% on these might be very challenging. So, first you need to check how much would your process energy for the manufacturing process be.For your energy model, ASHRAE 90.1 does not suggest a baseline value for the factory process, as every factory process would be very different and unique. So, you will need to create a baseline on your own. You may do this by looking at standard processes and equipments used by other chemical factories, set that as a baseline and try to model energy savings through the equipments and processes your project is using. Check if you propose to use high efficiency equipments. This in the end has to be acceptable by USGBC.For the energy model, you can consider using a software like IPMVP, which is quite flexible in developing baselines and calculating design case for different types of unique projects. There is also an option for using the default process energy of 25% for your process loads instead of the actual, which might make energy savings more possible.Bright task lighting and lower overhead lighting can also help in reducing overall energy for the project. ------------------Yongqing ZhaoChangsha Green Building & Energy Saving Technology CO.,LTD
NO.438,Shaoshan Road,Changsha,Hunan,China
Telephone:13574805636Email:zhaoyongqing1987 at 126.com         503271081 at qq.com  
_______________________________________________
Bldg-sim mailing list
http://lists.onebuilding.org/listinfo.cgi/bldg-sim-onebuilding.org
To unsubscribe from this mailing list send  a blank message to BLDG-SIM-UNSUBSCRIBE at ONEBUILDING.ORG


  
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/bldg-sim-onebuilding.org/attachments/20150326/720f0844/attachment.htm>


More information about the Bldg-sim mailing list