These warnings are not a big deal. They
are only saying the ceiling isn’t flat. The routines that create non-dimensional
vertical positions for each surface are using the average ceiling height. The
warning just says a surface is beyond the average ceiling and that will always
occur for a tilted ceiling. It’s a warning because the actual geometry
is more complex than what is assumed by method that makes surface heights non-dimensional.
Assuming you have checked the geometry is what you want, then they can be
ignored. From: Hello, The primary EnergyPlus web site is found at: http://www.energyplus.gov The group web site is: http://groups.yahoo.com/group/EnergyPlus_Support/ Attachments are not allowed -- please post any files to the appropriate folder in the Files area of the Support Web Site. EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.