I ran your file (window_geometry_simple_rectangular with Chicago
weather) here and it completed successfully.
Are you using the interim release as found on:
http://energyplus.helpserve.com/
On 6/14/2011 11:00 AM, Mathieu LAMOUR wrote:
Thank you for your response, and sorry if i'm not clear.
Of course my wall area is bigger than the glass one (in
fact, that's one of the think i ckecked with OpenStudio
plugin/Sketchup).
In the case that there are 36 windows of 1 m², there's a
wall (opaque) suface anyway, because its area is 3.4*3.4
m²
Thus, my windows, in all the cases, are included onto an
exterior wall (you can have a look at my .idf files if you
want).
I keep thinking that the problem may come from the "simple
method" or maybe from the big number of windows?
Thank you again
2011/6/14 Richard Raustad <RRaustad@xxxxxxxxxxxx>
....GenOpt to decide if the each window is 1
m² or 0.0000001 m².
The wall has to be bigger than the window
(i.e., there has to be wall area at the edge
of the glass). If your window is 1mx1m, then
the wall is all glass which would mean there
was no wall (or 0 wall area).
Try limiting the window size to 0.999 m2 to
0.001 m2
On 6/14/2011 10:40 AM, lamour.mathieu wrote:
Hi all,
I'm having some problems of « EnergyPlus
crashed », due to "forrtl:error
<65>: floating invalid".
I'm, for instance, just testing
something, coupling EPlus and GenOpt. So
It's a quite simple model (a cube 6*6*6
m), whom faces are divided into a "mesh"
of 36 squares (that will be a double
pane window or an opaque surface, except
for the floor).
For now, before implementing my GenOpt
model, I tried to run a simulation with
a nearly full glazed south surface, but
there occur my problem (with 36
windows). When I run with less windows,
it makes no problem, but trying with 36
windows, it indicates that EPlus
crashed. So I'm quite sure it comes from
my geometric model or from the "simple
method". Any idea about this?
The main problem is that I really need
to use the simple rectangular objects
(with X and Z origin and Length and
Height, for more convenience in my
GenOpt implementation). But :
- Writing my .idf file this way, I
verify the conform geometry into
OpenStudio's Sketchup plugin :
everything is fine, the windows appear
as I expect
- Running this same .idf file (without
any modification with OpenStudio), EPlus
crashes…
- So I export my .idf file from
sketchup, through OpenStudio plugin, and
I obtain the same windows, but with the
detailed vertex entry objects (that
means in my case 4 vertices, with their
coordinates "x, y, z"). I run a
simulation and… it works!
- The same happens with windows on each
faces
So I can't understand what's happening
with the simple rectangular objects
method… The fact is, one more time, that
I need to use this geometric description
method to facilitate my work with
GenOpt.
It's the 2nd time in few days that this
crash happens (the other time, it was
with another model, that I'd like to
present you in another post).
I really don't understand, for it's the
first time I have to face such a
problem. I tried to change some
parameters in my .idf file, but it's
still the same problem…
I uploaded the 2 files in Files >
_Problem_Submittals >
window_geometry_2methods
If anybody has an idea, it would be
great!
Thank you in advance
Waiting for instructions…
Mathieu
Ps : I know that, in a normal case, I
should design a single big window, but
the final goal is to make possible for
GenOpt to decide if the each window is 1
m² or 0.0000001 m². That's why I need so
many windows in each surface. I thought
it would take more calculation time, but
that it would work…
--
Richard A. Raustad
Senior Research Engineer
Florida Solar Energy Center
University of Central Florida
1679 Clearlake Road
Cocoa, FL 32922-5703
Phone: (321) 638-1454
Fax: (321) 638-1439 or 1010
Visit our web site at: http://www.fsec.ucf.edu
UCF - From Promise to Prominence: Celebrating 40 Years
--
Mathieu
--
Richard A. Raustad
Senior Research Engineer
Florida Solar Energy Center
University of Central Florida
1679 Clearlake Road
Cocoa, FL 32922-5703
Phone: (321) 638-1454
Fax: (321) 638-1439 or 1010
Visit our web site at: http://www.fsec.ucf.edu
UCF - From Promise to Prominence: Celebrating 40 Years
__._,_.___
Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx
The primary EnergyPlus web site is found at:
http://www.energyplus.gov
The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/
Attachments are currently allowed but be mindful that not everyone has a high speed connection. Limit attachments to small files.
EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.
__,_._,___
|