Re: [EnergyPlus_Support] no differences between results in PCM and reference





15 degrees sounds to be unreasonable, I found that I had the heating and cooling design days inverted, and fixed it.Try this one. Also look at the construction internal source, you may have to do two objects, one for each side, as the construction internal source goes from inside to outside--so your PCM may be canceling its self out by being on both. 
Also the brick you have placed in the middle may be an issue...

Try some experiments and let me know..

On Mon, Mar 5, 2012 at 11:24 AM, Mohammad Kheradmand <mohammadkheradmand@xxxxxxxxx> wrote:
 

I have a almost 15 degree difference between 12-16 PM. I saw the change in partition layer that you did. but i think it is incorrect,because we have same layer in both sides, what you think?

Sent: Monday, March 5, 2012 7:13 PM

Subject: Re: [EnergyPlus_Support] no differences between results in PCM and reference

 
Try this and let me know..

On Mon, Mar 5, 2012 at 11:02 AM, Mohammad Kheradmand <mohammadkheradmand@xxxxxxxxx> wrote:
 
I try to retrify experimental result, i cant move to outer wall, so it is necessary to be on outer layer of partition, my weather file refer to 2005 i don't  know, how can i convert to 2011 as a new one? also the thickness is fix .

thanks 


From: CleanTech Analytics <jeremiah@xxxxxxxxxxxxxxxxxxxxxx>
To: EnergyPlus_Support@xxxxxxxxxxxxxxx
Sent: Monday, March 5, 2012 6:28 PM
Subject: Re: [EnergyPlus_Support] no differences between results in PCM and reference

 
Try moving your PCM to an outer wall, or changing your weather file, or changing the thickness of your PCM.
Also make a spreadsheet that compares the two in terms of percent, as small savings in kWh for a single day may be bigger savings then it seems by just looking at kWh.

Let me know if you still have the issue after experiments..

On Mon, Mar 5, 2012 at 9:50 AM, Mohammad Kheradmand <mohammadkheradmand@xxxxxxxxx> wrote:
 
Could you please help me , what is wrong ? why i have, same results between two simulation?

regards



--
Jeremiah D. Crossett
CleanTech Analytics
This document may contain valuable information proprietary to CleanTech Analytics which is private and confidential. It may not be shared, copied, stored or transmitted in any form without the prior written consent of CleanTech Analytics






--
Jeremiah D. Crossett
CleanTech Analytics
This document may contain valuable information proprietary to CleanTech Analytics which is private and confidential. It may not be shared, copied, stored or transmitted in any form without the prior written consent of CleanTech Analytics






--
Jeremiah D. Crossett
CleanTech Analytics
503-688-8951
www.cleantechanalytics.com


This document may contain valuable information proprietary to CleanTech Analytics which is private and confidential. It may not be shared, copied, stored or transmitted in any form without the prior written consent of CleanTech Analytics




__._,_.___


Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx

The primary EnergyPlus web site is found at:
http://www.energyplus.gov

The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/

Attachments are currently allowed but be mindful that not everyone has a high speed connection.  Limit attachments to small files.

EnergyPlus Documentation is searchable.  Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.




Your email settings: Individual Email|Traditional
Change settings via the Web (Yahoo! ID required)
Change settings via email: Switch delivery to Daily Digest | Switch to Fully Featured
Visit Your Group | Yahoo! Groups Terms of Use | Unsubscribe

__,_._,___
Attachment not found:
d:\eudora\attach\wall with PCM (1)1.idf