[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[EnergyPlus_Support] Re: wind pressure coefficient array values
- To: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Subject: [EnergyPlus_Support] Re: wind pressure coefficient array values
- From: "lisacng" <lisa.ng@xxxxxxxx>
- Date: Thu, 12 Jul 2012 18:46:57 -0000
- Delivered-to: mailing list EnergyPlus_Support@xxxxxxxxxxxxxxx
- Delivery-date: Thu, 12 Jul 2012 12:47:00 -0600
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoogroups.com; s=lima; t=1342118819; bh=l3mfftS6tv1L8XMk97BP/JoxaQV0LuGfm5UQT8o2wWY=; h=Received:Received:X-Yahoo-Newman-Id:X-Sender:X-Apparently-To:X-Received:X-Received:X-Received:X-Received:X-Received:To:Message-ID:In-Reply-To:User-Agent:X-Mailer:X-Originating-IP:X-eGroups-Msg-Info:X-Yahoo-Post-IP:From:X-Yahoo-Profile:Sender:MIME-Version:Mailing-List:Delivered-To:List-Id:Precedence:List-Unsubscribe:Date:Subject:Reply-To:X-Yahoo-Newman-Property:Content-Type:Content-Transfer-Encoding; b=a+T40QtEONsMv0QW/MyokTRmLfWt2yUhI2YA/0s1kCYMk90DrssEY6SP2+VMemFuq4O+ktMAY9dAixvBj0jNmkn5NVaNxWTo3vEALUzVygkaAeNYDYTbcQvlJ3MWbg91
- Domainkey-signature: a=rsa-sha1; q=dns; c=nofws; s=lima; d=yahoogroups.com; b=Dcm9JGTB8BKGYg64TC74shg5u4EDFLFN7SrBzsToVNgfiFKzzIZ5We/fV4jjWWEYmPfXaoyCQrZvZu5M6y50l32VJZgAOs1q+X/SLM6FnjDSF5jRp32ejJmIjyUKNSNM;
- Envelope-to: linda@xxxxxxxxxxxxxx
- In-reply-to: <CAD7gt0XRddKqY5DHwJAXhgrHzY=cGYoE5COWrTgzXP+1A11t+Q@mail.gmail.com>
- List-id: <EnergyPlus_Support.yahoogroups.com>
- List-unsubscribe: <mailto:EnergyPlus_Support-unsubscribe@yahoogroups.com>
- Mailing-list: list EnergyPlus_Support@xxxxxxxxxxxxxxx; contact EnergyPlus_Support-owner@xxxxxxxxxxxxxxx
- Reply-to: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Sender: EnergyPlus_Support@xxxxxxxxxxxxxxx
- User-agent: eGroups-EW/0.82
We created CONTAM models of 16 reference buildings (here http://www.bfrl.nist.gov/IAQanalysis/case%20studies/cwcase_12.htm) and published a report on those models and our analyses. In the CONTAM models, we assumed a building tightness and let CONTAM calculate the infiltration. We assumed one wind pressure profile (Cp as a function of wind direction) for the buildings. You could use the same procedure.
Another tool you could use is Cp Generator (http://cpgen.bouw.tno.nl/cp/). Speaking of CFD, you can also use CONTAM CFD0 editor to generate wind pressure profiles.
Lisa
--- In EnergyPlus_Support@xxxxxxxxxxxxxxx, Vaibhav Jain <vaibhav.energyarchitect@...> wrote:
>
> Yes, CFD is needed to get Cp array values. If you ask E+ to calculate Cp
> for a rectangular building, then they remain constant either if you have
> many buildings/obstructions surrounding your building OR if you have an
> alone standing building. So from this, I understood that - for a complex
> geometry or when having surrounding obstructions, Cp values from CFD has to
> be brought in E+. I guess, wind tunnel should also be another option (for
> better results, but you might not want to do it).
>
> Vaibhav Jain
> www.vaibhavjain.co
>
>
>
>
> On 12 July 2012 13:47, tom.bee57 <tom.bee57@...> wrote:
>
> > **
> >
> >
> > Hi All,
> >
> > Forgive me if this has been covered, but I find nothing after a quick
> > search of the forum.
> >
> > I am interested how people go about getting the INPUT data for the wind
> > pressure coefficient array values.
> >
> > For a non-rectangular geomtery building, all other settings at their most
> > complicated. Do I need to solve a CFD problem to get the numbers ?
> >
> > Thanks
> >
> > Tom
> >
> >
> >
>
------------------------------------
Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx
The primary EnergyPlus web site is found at:
http://www.energyplus.gov
The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/
Attachments are currently allowed but be mindful that not everyone has a high speed connection. Limit attachments to small files.
EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.
Yahoo! Groups Links
<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/EnergyPlus_Support/
<*> Your email settings:
Individual Email | Traditional
<*> To change settings online go to:
http://groups.yahoo.com/group/EnergyPlus_Support/join
(Yahoo! ID required)
<*> To change settings via email:
EnergyPlus_Support-digest@xxxxxxxxxxxxxxx
EnergyPlus_Support-fullfeatured@xxxxxxxxxxxxxxx
<*> To unsubscribe from this group, send an email to:
EnergyPlus_Support-unsubscribe@xxxxxxxxxxxxxxx
<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/