[EnergyPlus_Support] EMS Mass Flow Rate
- To: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Subject: [EnergyPlus_Support] EMS Mass Flow Rate
- From: Nacho Gomis <nachogo27@xxxxxxxxx>
- Date: Thu, 24 Jan 2013 16:29:14 +0100
- Delivered-to: mailing list EnergyPlus_Support@xxxxxxxxxxxxxxx
- Delivery-date: Thu, 24 Jan 2013 08:30:24 -0700
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoogroups.com; s=echoe; t=1359041419; bh=Rht1zCpbjfbaIxinEn3Bz5MB0kSmnf3ms5TGg9Mgvu4=; h=Received:Received:X-Yahoo-Newman-Id:X-Sender:X-Apparently-To:X-Received:X-Received:X-Received:X-Received:X-Received:X-Received:Message-ID:To:X-Originating-IP:X-eGroups-Msg-Info:From:X-Yahoo-Profile:Sender:MIME-Version:Mailing-List:Delivered-To:List-Id:Precedence:List-Unsubscribe:Date:Subject:X-Yahoo-Newman-Property:Reply-To:Content-Type; b=P7FaChNGzJ3CSXQuk+SiBnJUGCpY5V8NLZRAjxnkoFQcItlfp/Tg0BbHv+wqdzRyhL1OFZKC1kg2ma5O/vhxIwjiD/qtJAYDYyyOFj414U2ZZs1MPpT9NrNDsxhYFXk8zC87Jx/Fr/hAu4G5zeg41Hkrk1KsoGW+bkpk8/371D8=
- Domainkey-signature: a=rsa-sha1; q=dns; c=nofws; s=echoe; d=yahoogroups.com; b=rLX60O6WZsMb1BMjphPxqUFR+V1QFxLuWb4p5UAuZ+k8SdIAa6hwcUobDbQF6lRDnjnHignL27hVwEtVkHoNhMageFKaCoHqdUIlciuZGvgH9jMddkAOGos3LIe/939SV0WnAoLM2/ecTX+4+6ZxMlgY9Z3HhdhiOQ8Nxqi5YUE=;
- Envelope-to: linda@xxxxxxxxxxxxxx
- List-id: <EnergyPlus_Support.yahoogroups.com>
- List-unsubscribe: <mailto:EnergyPlus_Support-unsubscribe@yahoogroups.com>
- Mailing-list: list EnergyPlus_Support@xxxxxxxxxxxxxxx; contact EnergyPlus_Support-owner@xxxxxxxxxxxxxxx
- Reply-to: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Sender: EnergyPlus_Support@xxxxxxxxxxxxxxx
Hello group,I'm trying to generate a default idf to be simulated with several weathers. This IDF contains an EMS to override the condenser flow rate, I set an variable flow rate. So my EMS sets the flow rate depending on my own rules.
The problem now it is I have a successful IDF for one weather, running without errors but this model doesn't have any autosize field for the pumps, I have filled all the autosize fields.
When I try to set, for example the Rated Flow Rate, to autosize I would need to reference my minimun flow rate, which is set in my EMS code, with a value from a EnergyPlus sensor. For exaple the 10% of the nominal flow rate.
Could someone help me with this issue?
P.S.: I have attached the working IDF and its weather.
__._,_.___
Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx
The primary EnergyPlus web site is found at:
http://www.energyplus.gov
The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/
Attachments are currently allowed but be mindful that not everyone has a high speed connection. Limit attachments to small files.
EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.
__,_._,___
Attachment not found:
d:\eudora\attach\FC-CH-3CND.idf
Attachment not found:
d:\eudora\attach\ESP_Malaga.084820_SWEC.epw