[EnergyPlus_Support] Ground source heat exchanger_ G-function [3 Attachments]
- To: <EnergyPlus_Support@xxxxxxxxxxxxxxx>
- Subject: [EnergyPlus_Support] Ground source heat exchanger_ G-function [3 Attachments]
- From: <silvia1-@xxxxxxxxxx>
- Date: 27 Oct 2013 10:06:30 -0700
- Delivered-to: mailing list EnergyPlus_Support@xxxxxxxxxxxxxxx
- Delivery-date: Sun, 27 Oct 2013 11:07:00 -0600
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoogroups.com; s=echoe; t=1382893618; bh=SbURkEWyanZ2XcF0+KFRApe3vtgHeT3KjBGgkS6gNkM=; h=Received:Received:X-Yahoo-Newman-Id:X-Sender:X-Apparently-To:X-Received:X-Received:X-Received:X-Received:X-Received:X-Received:X-Received:To:Message-ID:X-Mailer:X-Originating-IP:X-eGroups-Msg-Info:X-Yahoo-Post-IP:From:X-Yahoo-Profile:Sender:MIME-Version:Mailing-List:Delivered-To:List-Id:Precedence:List-Unsubscribe:Date:Subject:X-Yahoo-Newman-Property:Reply-To:Content-Type; b=qHCdMhTSrOmiEM3BUecH03XfM/Nw55VlfjhmwCKvaUilfZ/KrA+IYF5As2U0OKmfaIunYxN4+XSBjo1q7pu+SdbNM7dATVlR2eNLoWwdQUzmLundnkXOTLqsd1yvnPjHU/uBXl9527L3tqZVBb2vGFPRK3vYrJidXhk7VQV2g3Q=
- Domainkey-signature: a=rsa-sha1; q=dns; c=nofws; s=echoe; d=yahoogroups.com; b=5POyVq5pDMDVzND4dSCxA4LNL1YY0aO581n2sYgrH7Bg9bkPUP4ApQ9/r1t9ZxIfsw/T6kZ6nkodQB9cfjJWkrv/69FHu5ymj8RlsTY4xjYphk3xFidJiFP+GAHeQwVDkcBHr0pbKhlV+d5dlRbclwWIoxY9Z7kQgwgWLua9X8k=;
- Envelope-to: linda@xxxxxxxxxxxxxx
- List-id: <EnergyPlus_Support.yahoogroups.com>
- List-unsubscribe: <mailto:EnergyPlus_Support-unsubscribe@yahoogroups.com>
- Mailing-list: list EnergyPlus_Support@xxxxxxxxxxxxxxx; contact EnergyPlus_Support-owner@xxxxxxxxxxxxxxx
- Reply-to: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Sender: EnergyPlus_Support@xxxxxxxxxxxxxxx
Hi everybody.
I'm doing a simulation of an office building (5 storey, 4200 m2) combining an heat pump water-to-water system + vertical ground source heat exchanger with a four pipe fan coil system (in a second moment I will replace it with a radiant floor system) for heating and cooling.
I took the plant configuration from the GSHP-GLHE example file, but I'm not able to get the desidered temperature in my thermal zones and I guess is due to the configuration of the GHE. I understood that there is a software (GLHEPro) to calculate the g-function according to the building requirements, but I'm just a student who is doing this research for her final thesis and I cannot afford the purchased of a software.
Can someone give me some advice about my problem or send me some GHE configuration which could be fitted on a similar building?
Thank you everybody
__._,_.___
View attachments on the web
Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx
The primary EnergyPlus web site is found at:
http://www.energyplus.gov
The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/
Attachments are currently allowed but be mindful that not everyone has a high speed connection. Limit attachments to small files.
EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.
__,_._,___
Attachment not found:
d:\eudora\attach\TORB+GHE.idf
Attachment not found:
d:\eudora\attach\ITA_Torino.160590_IWEC.epw
Attachment not found:
d:\eudora\attach\TORB+GHE.svg