Re: [EnergyPlus_Support] Two different air loops / Node conection problem





Yes, I finally found this solution. Thank you !


On Tuesday, June 10, 2014 7:58 PM, "annie anniemarston@xxxxxxxxxxx [EnergyPlus_Support]" <EnergyPlus_Support@xxxxxxxxxxxxxxx> wrote:


 
If you put your two nodes in a node list, then put the name of that node list into equipment connections air inlet node spot your systems should run.

Annie

Sent from my iPhone

On Jun 10, 2014, at 6:08 PM, "ju.flamand@xxxxxxxxx [EnergyPlus_Support]" <EnergyPlus_Support@xxxxxxxxxxxxxxx> wrote:

 
Hi all, 

I try to model a single family house but have actually a problem with the HVAC systems.
 My house main zone is heated with an electric furnace and cooled with a window air conditioner. I had no problem to create the furnace air loop but when I add the window air conditioner, I have an error saying that the two air loops have the same outlet node (which is the zone inlet node) ...
I really don't know how to do, is there a way to have two inlet nodes for one zone ?

Regards,

Julie Flamand
<st-stg-62760.idf>




__._,_.___

Posted by: Julie Flamand <ju.flamand@xxxxxxxxx>


Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx

The primary EnergyPlus web site is found at:
http://www.energyplus.gov

The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/

Attachments are currently allowed but be mindful that not everyone has a high speed connection.  Limit attachments to small files.

EnergyPlus Documentation is searchable.  Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.




Visit Your Group
Yahoo! Groups
PrivacyUnsubscribeTerms of Use

__,_._,___