[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[EnergyPlus_Support] Inserting a Coil:Electric:Heating on a Fancoil
- To: <EnergyPlus_Support@xxxxxxxxxxxxxxx>
- Subject: [EnergyPlus_Support] Inserting a Coil:Electric:Heating on a Fancoil
- From: "felipe@xxxxxxxxxx [EnergyPlus_Support]" <EnergyPlus_Support@xxxxxxxxxxxxxxx>
- Date: 21 Sep 2014 05:42:09 -0700
- Delivered-to: mailing list EnergyPlus_Support@xxxxxxxxxxxxxxx
- Delivery-date: Sun, 21 Sep 2014 06:42:18 -0600
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoogroups.com; s=echoe; t=1411303330; bh=BUKZtUhMh/QoIStwldMxoEo3Ti8hfA9H6uWCnTW5Pyw=; h=Received:Received:X-Yahoo-Newman-Id:X-Sender:X-Apparently-To:X-Received:X-Received:X-Received:X-Received:X-Received:X-Received:X-Received:To:Message-ID:X-Mailer:X-Original-From:X-Originating-IP:X-Yahoo-Post-IP:From:X-Yahoo-Profile:Sender:MIME-Version:Mailing-List:Delivered-To:List-Id:Precedence:List-Unsubscribe:Date:Subject:Reply-To:X-Yahoo-Newman-Property:Content-Type; b=evjM0YQS6RAGoADkZc0sjSZTsOK3W60GPhj3hu73YlzBpa7rAfjCQk0FFALNzcG5UZgl0NUKSm0LCoQP2RBMwbwo42kYjAj2rbsB2yP4s9PBK1Dc/APMjj8aYnWEct+yOh5cZLwNEXLmcDTaLExaNttn2SOY4jrR4HmiGpx6rYg=
- Domainkey-signature: a=rsa-sha1; q=dns; c=nofws; s=echoe; d=yahoogroups.com; b=luEDxCLtAtaeJaT7wN7KoV2TXXl8POenACV/WjJPKfmMxGpEdUMNr0Q/3CMx1y17WfPGZr1RwODjPOliKWTkyM4F6LlkMxPHdp5NeYrkshMOitmEl2NlhgGI7uluSfZtlw82aEC29aVvtGNNwD2Yy1QRmTCZiaBVsYNKVnAJRQU=;
- Envelope-to: linda@xxxxxxxxxxxxxx
- List-id: <EnergyPlus_Support.yahoogroups.com>
- List-unsubscribe: <mailto:EnergyPlus_Support-unsubscribe@yahoogroups.com>
- Mailing-list: list EnergyPlus_Support@xxxxxxxxxxxxxxx; contact EnergyPlus_Support-owner@xxxxxxxxxxxxxxx
- Reply-to: EnergyPlus_Support@xxxxxxxxxxxxxxx
Dear Group,
I need to model a 2 pipe fan coil unit with an electric resistance for heating. I initially modeled it as a HVAC Template:Zone:Fan Coil with a electric boiler and with a with 0W pump power. The LEED reviewer told me that, since energyplus is able to model a electric resistance on a fan coil unit, I should model it as it is. He suggest me to turn off the water heating coil and that I simply insert the Coil:Heating:Electric on a expanded IDF.
Is that possible?
Has any of you have tried this before?
Kind Regards,
Felipe Durán
__._,_.___
Posted by: felipe@xxxxxxxxxx
Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx
The primary EnergyPlus web site is found at:
http://www.energyplus.gov
The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/
Attachments are currently allowed but be mindful that not everyone has a high speed connection. Limit attachments to small files.
EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.
__,_._,___