Re: [EnergyPlus_Support] PMV





What is the calling point of EMS program calling manager? Did you try EndOfZoneTimeStepBeforeZoneReporting?

EnergyManagementSystem:Sensor,
PMVWZ, !Name
West Zone,! Output:Variable or Output:Meter Index Key Name
Zone Thermal Comfort Fanger Model PMV; ! Output:Variable or Output:Meter Name

EnergyManagementSystem:Sensor,
PMVEZ, !Name
East Zone,! Output:Variable or Output:Meter Index Key Name
Zone Thermal Comfort Fanger Model PMV; ! Output:Variable or Output:Meter Name

EnergyManagementSystem:ProgramCallingManager,
FangerAveragePredictedMeanVote, ! Name
EndOfZoneTimestepBeforeZoneReporting , ! EnergyPlus Model Calling Point
FangerPMVProgram; ! Program Name 1

EnergyManagementSystem:GlobalVariable,
WZPMV;

EnergyManagementSystem:GlobalVariable,
EZPMV;

EnergyManagementSystem:OutputVariable,
West Zone Predicted Mean Vote, ! Name
WZPMV, ! EMS Variable Name
Averaged, ! Type of Data in Variable
ZoneTimeStep ; ! Update Frequency

EnergyManagementSystem:OutputVariable,
East Zone Predicted Mean Vote, ! Name
EZPMV, ! EMS Variable Name
Averaged, ! Type of Data in Variable
ZoneTimeStep ; ! Update Frequency

EnergyManagementSystem:Program,
FangerPMVProgram, ! Name
SET WZPMV = PMVWZ,
SET EZPMV = PMVEZ,
SET NZPMV = PMVNZ;

Output:Variable,
*, !- Key Value
Zone Thermal Comfort Fanger Model PMV, !- Variable Name
hourly; !- Reporting Frequency

Output:Variable,
*, !- Key Value
West Zone Predicted Mean Vote, !- Variable Name
hourly; !- Reporting Frequency

Output:Variable,
*, !- Key Value
East Zone Predicted Mean Vote, !- Variable Name
hourly; !- Reporting Frequency


On Tuesday 23 September 2014 10:25 PM, Fakeha Sehar fakeha_s@xxxxxxxxx [EnergyPlus_Support] wrote:
 
when defining the Erl output variable "type of data in variable" i do define them as average, if thats what you mean.
EnergyManagementSystem:Output variable
Name:
EMS Variable name:
Type of data in variable: Averaged
Update frequency: Zone Timestep


On Tuesday, September 23, 2014 12:20 PM, "Jeremiah Crossett jcrossett@xxxxxxxxxxxxxxx [EnergyPlus_Support]" <EnergyPlus_Support@xxxxxxxxxxxxxxx> wrote:


 
You may want to do some type of averaging as I think the standard outputs do, average between the time-steps that is. 



​​
Jeremiah D. Crossett  | Senior Analyst  LEED Green Associate 
​​
120 E. Pritchard St.  | Asheboro, NC 27203 
​​
 | Mobile 503-688-8951
  




On Tue, Sep 23, 2014 at 7:57 AM, Fakeha Sehar fakeha_s@xxxxxxxxx [EnergyPlus_Support] <EnergyPlus_Support@xxxxxxxxxxxxxxx> wrote:
 
I am sensing the Zone Thermal Confort Fanger PMV values. I am then using them in IF statements and have them as Erl outputs. On the other hand, I am also viewing the regular zone thermal comfort Fanger PMVvalues as output. Problem is these two outputs Erl PMV values and regular PMV values for the zones should be same but they are not. Why?
For example at 16:20 Erl PMV values for top floor perimeter zone 4 is EMS:Erl Top Flr Zone 4 PMV[] (TimeStep)=  0.58
but regular PMV output for zone 4 top floor is PERIMETER_TOP_ZN_4 PEOPLE:Zone Thermal Comfort Fanger Model PMV [](TimeStep)=0.26.
 






__._,_.___

Posted by: Chandan <chandangsharma@xxxxxxxxx>


Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx

The primary EnergyPlus web site is found at:
http://www.energyplus.gov

The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/

Attachments are currently allowed but be mindful that not everyone has a high speed connection.  Limit attachments to small files.

EnergyPlus Documentation is searchable.  Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.





__,_._,___