[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [EnergyPlus_Support] SurfaceProperty:OtherSideCoefficients





Ahhh. That makes sense. Thanks.

Mit freundlichen GrüÃ?en- Sent from my iPhone (excuse the brevity)

i. A.
Jean Marais
b.i.g. bechtold
Tel.   +49 30 6706662-23

On 25.11.2014, at 16:30, "'Brent Griffith' brent.griffith@xxxxxxxxxxxxxxxxxx [EnergyPlus_Support]" <EnergyPlus_Support@xxxxxxxxxxxxxxx> wrote:

 

    0,                       !- Combined Convective/Radiative Film Coefficient {W/m2-K}

 

I think you need to set this film coefficient to something high, like 1000 W/m2-K.  

 

From: EnergyPlus_Support@xxxxxxxxxxxxxxx [mailto:EnergyPlus_Support@xxxxxxxxxxxxxxx]
Sent: Tuesday, November 25, 2014 6:20 AM
To: EnergyPlus_Support@xxxxxxxxxxxxxxx
Subject: [EnergyPlus_Support] SurfaceProperty:OtherSideCoefficients

 

 


Dear Modellers

I want to set the external side of a surface to 21deg.C constant. This surface is an outside surfice facing the external environment. I am using SurfaceProperty:OtherSideCoefficients and I cannot get the desired result.
Anyone has experience with this E+ object?
---------------------------------------------------------
SurfaceProperty:OtherSideCoefficients,
    OtherSide_21deg_constant,!- Name
    0,                       !- Combined Convective/Radiative Film Coefficient {W/m2-K}
    21,                      !- Constant Temperature {C}
    1,                       !- Constant Temperature Coefficient
    0,                       !- External Dry-Bulb Temperature Coefficient
    0,                       !- Ground Temperature Coefficient
    0,                       !- Wind Speed Coefficient
    0,                       !- Zone Air Temperature Coefficient
    Always 21degC,           !- Constant Temperature Schedule Name
    No;                      !- Sinusoidal Variation of Constant Temperature Coefficient
--------------------------------------------------------
I am using this to get the surface temperature of the surfaces of interest. Is this right?

-----------------------------------------------------------
Output:Variable,
    LEVEL1.00:AHU01_Wall_4_0_0_0_0_0_Subsurface,  !- Key Value
    Surface Outside Face Temperature ,  !- Variable Name
    Timestep;                !- Reporting Frequency

Output:Variable,
    LEVEL6.50:AHU03_Wall_9_0_0_0_0_0_Subsurface,  !- Key Value
    Surface Outside Face Temperature ,  !- Variable Name
    Timestep;                !- Reporting Frequency

-----------------------------------------------------------

 

Thanks

Luis

 



__._,_.___

Posted by: "jeannieboef@xxxxxxxxx" <jeannieboef@xxxxxxxxx>


Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx

The primary EnergyPlus web site is found at:
http://www.energyplus.gov

The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/

Attachments are currently allowed but be mindful that not everyone has a high speed connection.  Limit attachments to small files.

EnergyPlus Documentation is searchable.  Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.





__,_._,___