Try using Run with brackets in the ##set line, like:

##set1 Run[] 1



On 3/7/2016 3:28 AM, pranav.godbole@xxxxxxxxx [EnergyPlus_Support] wrote:

Hello,


In order to try out the E+ Input Macros, I created an IMF file based on an example E+ file. the file name is "5ZoneAirCooled _Trial.IMF" and it is uploaded under the files section of this support group. The IMF file contains one ##Set1  keyword and one ##if ##else loop. 


Here's what I am trying to do. Set "Run" = 1. If Run = 1, the thickness of material IN02 is 9.0099998E-02, otherwise it's 18.0099998E-02. The EP-Launch runs the IMF file without any errors, but the thickness remains 9.0099998E-02 irrespective of the numerical value assigned to "Run" (confirmed by checking the EPMDET file).


Are there any rules for where the macro ## keywords could be specified in the IMF file? I did not find any mention of the rules "AuxiliaryPrograms" pdf document.


Help  in this regard is appreciated!


Regards,

Pranav



-- 
Jason Glazer, P.E., GARD Analytics, 90.1 ECB chair
Admin for onebuilding.org building performance mailing lists


__._,_.___

Posted by: Jason Glazer <jglazer@xxxxxxxx>


Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx

The primary EnergyPlus web site is found at:
http://www.energyplus.gov

The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/

Attachments are currently allowed but be mindful that not everyone has a high speed connection.  Limit attachments to small files.

EnergyPlus Documentation is searchable.  Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.





__,_._,___