[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[EnergyPlus_Support] Airflownetwork Ventilation control - upper limit
- To: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Subject: [EnergyPlus_Support] Airflownetwork Ventilation control - upper limit
- From: "nedimho@xxxxxxxx [EnergyPlus_Support]" <EnergyPlus_Support@xxxxxxxxxxxxxxx>
- Date: 04 Oct 2019 04:25:04 -0700
- Authentication-results: mta4002.groups.mail.bf1.yahoo.com; dkim=pass (ok) header.i=@yahoogroups.com header.s=echoe; spf=pass smtp.mailfrom=@yahoogroups.com; dmarc=pass(p=none sp=NULL dis=none) header.from=yahoogroups.com;
- Authentication-results: mta4003.groups.mail.bf1.yahoo.com; dkim=pass (ok) header.i=@yahoogroups.com header.s=echoe; spf=pass smtp.mailfrom=@yahoogroups.com; dmarc=pass(p=none sp=NULL dis=none) header.from=yahoogroups.com;
- Delivered-to: linda@xxxxxxxxxxxxxx
- Delivered-to: mailing list EnergyPlus_Support@xxxxxxxxxxxxxxx
- Delivery-date: Fri, 04 Oct 2019 05:49:21 -0600
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoogroups.com; s=echoe; t=1570189749; bh=uhtkGxf74Ghlgj/QUvWyAMCV4lSlZhfOv+6pgNmvz3g=; h=From:To:List-Id:List-Unsubscribe:Date:Subject:Reply-To:From:Subject; b=iz3Qrh10YLtQ9Ccol0V+L816FuRntWIKZVb/SoaoPHO+1Vp70wNoPlM6hm8pKv1wpNL3kn3TlpRVX9Ey18PePiN5bi1qJIlXsbsdQXC2238jMLh6BS6sHtTz753XFkqbCHculmMqu2MdxL94TRH5h6TwxTiVD3bfsJE675ECMXY=
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoogroups.com; s=echoe; t=1570188393; bh=5jXBYfF1PbpmBfonr9GWQw5Sb95texRWTVNC5wUhvuI=; h=Date:Subject:From:Reply-To:To:From:Subject; b=2MRu/bOxPh8rysxIyjHxa3EIOGWuogFDwAb/bJXfsE5firqyzH0u99bkuiM+SO6Reax4u0V8723ezYTOsu21T7lnX0fNU6XZRmupJ+U6jQFQN1FXkulSCL113e+ZLmhEoGpYUQx+WVhPY3C6y119V2RR0YTpVyHR//RvQlnrmME=
- Envelope-to: linda@xxxxxxxxxxxxxx
- List-id: <EnergyPlus_Support.yahoogroups.com>
- List-unsubscribe: <mailto:EnergyPlus_Support-unsubscribe@yahoogroups.com>
- Mailing-list: list EnergyPlus_Support@xxxxxxxxxxxxxxx; contact EnergyPlus_Support-owner@xxxxxxxxxxxxxxx
- Reply-to: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Sender: EnergyPlus_Support@xxxxxxxxxxxxxxx
Hello!
I used the AirflowNetwork objects to simulate a naturally ventilated Greenhouse.
First results are in and everything works fine appart from the fact that I cannot seem to limit the maximum ventilation rate. At some points I get infiltration air change rates of 136 1/h.
I would like to limit the air change rates to a maximum of 30.
Is that possible? Should I do it via schedule or another object? In the objects that I've used the only defineable upper limit that I could find is the Enthalpy difference. I don't really know if control through enthalpy is the right way?
Thanks in advance!
__._,_.___
Posted by: nedimho@xxxxxxxx
EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx
The EnergyPlus web site is found at:
http://www.energyplus.net/
The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/
Attachments are currently allowed but be mindful that not everyone has a high speed connection. Limit attachments to small files.
EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.
__,_._,___