[Equest-users] window switching crashing eQuest v3.64

deepika khowal deepika.khowal at gmail.com
Tue Oct 9 09:47:06 PDT 2012


yes that's correct.

The switching capability doesn't work for simplified windows.

Pls let me know if you still have trouble modeling this.

Thanks


On Tue, Oct 9, 2012 at 9:37 AM, James Hansen <JHANSEN at ghtltd.com> wrote:

> Thank you Deepika.  Just found this in the Topics PDF:****
>
> ** **
>
> *The GLASS-TYPE keyword accepts the U-name of the glass types for the
> unswitched (clear) state and GLASS-TYPE-SW accepts the U-name of the glass
> type for the *
>
> *fully switched (colored) state.  Both of these glass types have
> GLASS-TYPE-CODE > 1000 and must be chosen from the library (see "Window
> Library Method"). *
>
> *An error will result if the number of glass layers is different for
> GLASS-TYPE and GLASS-TYPE-SW.*
>
> ** **
>
> So it looks like you can't model simplified U-value/SC windows.****
>
> ** **
>
> *GHT Limited
> **James Hansen, P.E., LEED AP*
> Senior Associate
> 1010 N. Glebe Road, Suite 200
> Arlington, VA  22201-4749
> 703-243-1200 (office)****
>
> 703-338-5754 (cell)
> 703-276-1376 (fax)****
>
> www.ghtltd.com****
>
> ** **
>
> *From:* Deepika [mailto:deepika.khowal at gmail.com]
> *Sent:* Tuesday, October 09, 2012 11:52 AM
> *To:* James Hansen
> *Cc:* <equest-users at lists.onebuilding.org>
> *Subject:* Re: [Equest-users] window switching crashing eQuest v3.64****
>
> ** **
>
> James ****
>
> Which window pair are you using from the library ?****
>
> ** **
>
> You have to make sure you use the right pair else it will crash .****
>
> ** **
>
> Also confirm that you selected the clear as your window type and then
> chose the tinted as switch type
>
> On Oct 9, 2012, at 7:25 AM, "James Hansen" <JHANSEN at ghtltd.com> wrote:****
>
> Has anyone successfully applied window switching in eQuest?  I'm trying,
> and it crashes, regardless of whether I try and enter the parameters in
> eQuest or in the DOE-2 input file.  Just trying a simple TOT-SOL-INC
> variable, but none of the switching methods seem to work.  I can define the
> switched window manually, but as soon as I try and select a switch type, it
> crashes.****
>
>  ****
>
> Anyone else experience this?  Thanks!****
>
>  ****
>
> (I searched for this, found a few references to eQuest crashing, but no
> fixes)****
>
>  ****
>
> *GHT Limited
> **James Hansen, P.E., LEED AP*
> Senior Associate
> 1010 N. Glebe Road, Suite 200
> Arlington, VA  22201-4749
> 703-243-1200 (office)****
>
> 703-338-5754 (cell)
> 703-276-1376 (fax)****
>
> www.ghtltd.com****
>
>  ****
>
> _______________________________________________
> Equest-users mailing list
> http://lists.onebuilding.org/listinfo.cgi/equest-users-onebuilding.org
> To unsubscribe from this mailing list send  a blank message to
> EQUEST-USERS-UNSUBSCRIBE at ONEBUILDING.ORG****
>
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20121009/ddf5a1f4/attachment-0002.htm>


More information about the Equest-users mailing list