[Equest-users] Section 179D Question
David Eldridge
DEldridge at grummanbutkus.com
Fri Apr 25 17:41:50 PDT 2014
This is encouraging! Still a long ways to go before it is law, but it could be a smart move to keep this in mind for current 2014 projects which will most likely be retroactively eligible if it is approved in the near future.
DSE Mobile
On Apr 25, 2014, at 10:02 AM, "Tom Mickley" <tmickley at thekcompany.com<mailto:tmickley at thekcompany.com>> wrote:
I haven't had the time this morning to read all of the email responses yet, but I have a coworker email this website this morning which is what sparked my interest originally.
http://www.nema.org/News/Pages/NEMA-Commends-Senate-Finance-Committees-Extension-of-179D-Tax-Deduction.aspx
Thank you all for the responses by the way.
Thanks,
Tom Mickley
Mechanical Engineer CEM
The K Company
Cell 330-760-3994
Office 330-773-5125
From: David Eldridge [mailto:DEldridge at grummanbutkus.com]
Sent: Friday, April 25, 2014 10:49 AM
To: Steve Jacobs; Tom Mickley; Busby, Aaron
Cc: equest-users at lists.onebuilding.org<mailto:equest-users at lists.onebuilding.org>
Subject: Re: [Equest-users] Section 179D Question
Tom the original poster:
When you say "proposing" do you mean the project wasn't completed some time between 2005 and 2013?
I see a bigger hiccup relating to the legislation not being currently extended into 2014, unless this happened recently.
Other major hiccups:
1) $1.80 deduction is only if all three paths are pursued - envelope, HVAC, and electrical. What you described here was only HVAC measures.
2) it's a deduction and not a credit...so your client with 100,000 sf is looking at $60,000 deduction, for which their net value may be ~$20,000 or less depending on many other factors outside of the efficiency work itself.
DSE Mobile
On Apr 25, 2014, at 9:39 AM, "Steve Jacobs" <sjacobseng at gmail.com<mailto:sjacobseng at gmail.com>> wrote:
I'm not aware of anything says we can or can't use addendum to Appendix G. It is certainly frustrating not having anywhere to take questions. The inability for modelers to seek clarifications means that the community is probably taking a lot of different approaches to the incentive.
On 4/25/2014 6:56 AM, Busby, Aaron wrote:
ASHRAE 90.1 has several addendums now that have added system types, just for warehouse type spaces where they are heated only. Look for Addenda DN, system types 10 and 11.
Aaron Busby, PE, LEED AP
Tel: 770.563.1522
Cell: 678.642.7549
From: equest-users-bounces at lists.onebuilding.org<mailto:equest-users-bounces at lists.onebuilding.org> [mailto:equest-users-bounces at lists.onebuilding.org] On Behalf Of Tom Mickley
Sent: Friday, April 25, 2014 8:38 AM
To: equest-users at lists.onebuilding.org<mailto:equest-users at lists.onebuilding.org>
Subject: [Equest-users] Section 179D Question
Has anyone run a baseline building for a retrofit building to qualify a business owner for the Section 179D tax deduction? It seems simple enough to model the existing building based on ASHRAE 90.1 standards. Has anyone found any potential "hiccups" along the way that has prevented the up to $1.80/sq tax deduction aside from the obvious of not meeting the energy upgrade percentage?
Here's my main concern. I have a cabinet manufacturer customer who has a 100,000sf metal building that is roughly 30% wood working or manufacturing, 65% warehouse storage and 5% office space. 95% of this facility is heated only. Do I have to include cooling in the baseline from ASHRAE 90.1 system 5 on appendix G, table G3.1.1.A? The only upgrades we are proposing are to take out the air rotation unit and radiant tube vacuum systems and a few other minor items.
Any advice would help. Thanks in advance.
Thanks,
Tom Mickley
Mechanical Engineer CEM
The K Company
Cell 330-760-3994
Office 330-773-5125
_______________________________________________
Equest-users mailing list
http://lists.onebuilding.org/listinfo.cgi/equest-users-onebuilding.org
To unsubscribe from this mailing list send a blank message to EQUEST-USERS-UNSUBSCRIBE at ONEBUILDING.ORG<mailto:EQUEST-USERS-UNSUBSCRIBE at ONEBUILDING.ORG>
_______________________________________________
Equest-users mailing list
http://lists.onebuilding.org/listinfo.cgi/equest-users-onebuilding.org
To unsubscribe from this mailing list send a blank message to EQUEST-USERS-UNSUBSCRIBE at ONEBUILDING.ORG<mailto:EQUEST-USERS-UNSUBSCRIBE at ONEBUILDING.ORG>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/equest-users-onebuilding.org/attachments/20140426/19a178d5/attachment-0002.htm>
More information about the Equest-users
mailing list