[TRNSYS-users] TRNDll.dll missing

David BRADLEY d.bradley at tess-inc.com
Tue May 28 13:50:00 PDT 2013


Hao,
   If you are getting such an error and you are using Type907 from the 
TESS CHP library then check to make sure that there is a file called 
TESSCogenLibrary_v17.1.00_Release.dll in the 
..\Trnsys17\UserLib\ReleaseDLLs\ directory. If there is not then it may 
be that the TESS CHP library did not install correctly.
Kind regards,
  David


On 5/27/2013 08:31, 吴昊 wrote:
>
> Dear all,
>
> My name is Hao and i am from university of Kassel. I am buiding a 
> model for CHP System and i have used a component named IC Engines 
> (type 907). When i run simulation, it appears the following error:
>
> A TYPE was called in the TRNSYS input file but was either not linked 
> into trndll.dll or was not found in an external dll. A dummy 
> subroutine was called in its place. Please link the TYPE or remove it 
> from the input file
>
> And with the reported information
>
> Type907 could not be located in either the trndll.dll or in an 
> external dll. Please relink theTRNDll.dll including this Type or make 
> sure that an external DLL in the \UserLib\DebugDLLs and 
> \UserLib\ReleaseDLLs folders contain the Type.
>
> Could anyone help me? I don't understand this message,is something 
> missing from the component "type 907" or should i do something in 
> fortran befor the simulation?
>
> Thank you in advance.
>
> Best regards
> Hao
>
>
>
>
> _______________________________________________
> TRNSYS-users mailing list
> TRNSYS-users at cae.wisc.edu
> https://mailman.cae.wisc.edu/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley at tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com

-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.onebuilding.org/pipermail/trnsys-users-onebuilding.org/attachments/20130528/a48d9b95/attachment-0001.htm>


More information about the TRNSYS-users mailing list