[EnergyPlus_Support] difference betw. output variables
- To: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Subject: [EnergyPlus_Support] difference betw. output variables
- From: "tobias.leibing" <tobias.leibing@xxxxxx>
- Date: Fri, 06 Nov 2009 21:58:04 -0000
- Delivered-to: mailing list EnergyPlus_Support@xxxxxxxxxxxxxxx
- Delivery-date: Fri, 06 Nov 2009 14:59:08 -0700
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoogroups.com; s=lima; t=1257544748; bh=LJsMElwd3PlsdzC4XlRJlfZvJW08Ld/btzucNdISVsc=; h=Received:Received:X-Yahoo-Newman-Id:X-Sender:X-Apparently-To:X-Received:X-Received:X-Received:X-Received:X-Received:To:Message-ID:User-Agent:X-Mailer:X-Originating-IP:X-eGroups-Msg-Info:X-Yahoo-Post-IP:From:X-Yahoo-Profile:Sender:MIME-Version:Mailing-List:Delivered-To:List-Id:Precedence:List-Unsubscribe:Date:Subject:Reply-To:X-Yahoo-Newman-Property:Content-Type:Content-Transfer-Encoding; b=W7smJWv6VFx8NleV31BnaeRPwvtg+5vInxCfaNnbVnAqiJp3wO4FamvKvdzny+B8D2IEYBsU7kvB97vD1dEVbDONYMoCQJbgt9o6+xQQWDcNlhoZoX0e5ghatUZXxlqD
- Domainkey-signature: a=rsa-sha1; q=dns; c=nofws; s=lima; d=yahoogroups.com; b=XNbWPHIx2YqfJDTHhisB6vhpCi9BDjZO6JnPpXjLCIJw+zjOoc8a184rtMDhCVhX8BJ8f1RMVoP1NzqRLtWfM4+cahWB5lgA602CjnfwI+gBW9v3hupKc54eVErOK4R4;
- Envelope-to: linda@xxxxxxxxxxxxxx
- List-id: <EnergyPlus_Support.yahoogroups.com>
- List-unsubscribe: <mailto:EnergyPlus_Support-unsubscribe@yahoogroups.com>
- Mailing-list: list EnergyPlus_Support@xxxxxxxxxxxxxxx; contact EnergyPlus_Support-owner@xxxxxxxxxxxxxxx
- Reply-to: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Sender: EnergyPlus_Support@xxxxxxxxxxxxxxx
- User-agent: eGroups-EW/0.82
Hey there,
I was comparing the different available output variables of my model to figure out which ones are the best for my purposes.
There I came across the following:
I have specified an efficiency of 0.9 (180kW) which is mirrored in these two outputs.
AHU5_HC:Heating Coil Energy[J](Hourly)
6.48E+08
AHU5_HC:Heating Coil Electric Consumption [J](Hourly)
7.20E+08
However, if I take a look on the Air Loop outputs, the numbers for the consumption don't match up any more whereas the heating coil energy remains the same.
AHU5:Air Loop Total Heating Coil Energy[J](Hourly)
6.48E+08
AHU5:Air Loop Heating Coil Electric Consumption[J](Hourly)
1.37E+09
Does anyone have an idea what the reason for that might be??
Besides, the Air Loop Total Heating Energy is slightly higher than the one of just the coil.
AHU5:Air Loop Total Heating Energy[J](Hourly)
6.50E+08
Does this reflect the heat added to the air by the fan?
Thanks,
Tobias
------------------------------------
The primary EnergyPlus web site is found at:
http://www.energyplus.gov
The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/
Attachments are currently allowed but be mindful that not everyone has a high speed connection. Limit attachments to small files.
EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.
Yahoo! Groups Links
<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/EnergyPlus_Support/
<*> Your email settings:
Individual Email | Traditional
<*> To change settings online go to:
http://groups.yahoo.com/group/EnergyPlus_Support/join
(Yahoo! ID required)
<*> To change settings via email:
EnergyPlus_Support-digest@xxxxxxxxxxxxxxx
EnergyPlus_Support-fullfeatured@xxxxxxxxxxxxxxx
<*> To unsubscribe from this group, send an email to:
EnergyPlus_Support-unsubscribe@xxxxxxxxxxxxxxx
<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/