[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[EnergyPlus_Support] HVACStandAloneERV with variable outdoor air flow rate?
- To: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Subject: [EnergyPlus_Support] HVACStandAloneERV with variable outdoor air flow rate?
- From: "Joao Rosa" <jlcvrosa@xxxxxxxxx>
- Date: Tue, 06 Jul 2010 23:36:35 -0000
- Delivered-to: mailing list EnergyPlus_Support@xxxxxxxxxxxxxxx
- Delivery-date: Tue, 06 Jul 2010 17:37:25 -0600
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoogroups.com; s=lima; t=1278459411; bh=jD+FFKwO2cBl5XDvLyXuxIo3K1s/ZdWHqZX0/7fBqCA=; h=Received:Received:X-Yahoo-Newman-Id:X-Sender:X-Apparently-To:X-Received:X-Received:X-Received:X-Received:X-Received:X-Received:To:Message-ID:User-Agent:X-Mailer:X-Originating-IP:X-eGroups-Msg-Info:X-Yahoo-Post-IP:From:X-Yahoo-Profile:Sender:MIME-Version:Mailing-List:Delivered-To:List-Id:Precedence:List-Unsubscribe:Date:Subject:Reply-To:X-Yahoo-Newman-Property:Content-Type:Content-Transfer-Encoding; b=oVjHkCwjI7OV58V45uD3ds6IIpLTb+/SL3w6CfVF3MVKESdM7QnMMrE1jPcam3y7kn6DeRRhzRUGJRrdIrnIVpg1jeGmGzddm4LdeosTRjazmeDcBLXBbEO5eAQEzLoM
- Domainkey-signature: a=rsa-sha1; q=dns; c=nofws; s=lima; d=yahoogroups.com; b=F/nNoMMryOZ4hQny6VUCc68pR+AQDN/niM8erhAwrCo2kGqNlcNAKWybQuzxO/zjfJiW40GkUkaSBVoc2MaROaQOYKHTPSsFAbHVLE0Lj6wxhXPGJOPpmArAFQpIxNfz;
- Envelope-to: linda@xxxxxxxxxxxxxx
- List-id: <EnergyPlus_Support.yahoogroups.com>
- List-unsubscribe: <mailto:EnergyPlus_Support-unsubscribe@yahoogroups.com>
- Mailing-list: list EnergyPlus_Support@xxxxxxxxxxxxxxx; contact EnergyPlus_Support-owner@xxxxxxxxxxxxxxx
- Reply-to: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Sender: EnergyPlus_Support@xxxxxxxxxxxxxxx
- User-agent: eGroups-EW/0.82
Hello,
I want to model a ERV system setting up the outdoor air flow rate according to the ocupation (m3/s.person). I have an occupation shedule with the percentages of occupation to define the hourly air flow rate but in all of my experiments the air flow rate is always constant( the maximum value at 100% occupation).
It is possible with this system not to have a constant outdoor air flow rate?
Thanks for your help
------------------------------------
Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx
The primary EnergyPlus web site is found at:
http://www.energyplus.gov
The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/
Attachments are currently allowed but be mindful that not everyone has a high speed connection. Limit attachments to small files.
EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.
Yahoo! Groups Links
<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/EnergyPlus_Support/
<*> Your email settings:
Individual Email | Traditional
<*> To change settings online go to:
http://groups.yahoo.com/group/EnergyPlus_Support/join
(Yahoo! ID required)
<*> To change settings via email:
EnergyPlus_Support-digest@xxxxxxxxxxxxxxx
EnergyPlus_Support-fullfeatured@xxxxxxxxxxxxxxx
<*> To unsubscribe from this group, send an email to:
EnergyPlus_Support-unsubscribe@xxxxxxxxxxxxxxx
<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/