[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [EnergyPlus_Support] RVI or MVI files?





Niraj,
I do not think you will need the ",annual"
So It should look like:

eplusout.eso
eplusout.csv
Zone/Sys Sensible Cooling
Zone/Sys Sensible Heating
0

jE+ will use those values (so long as you have them in your IDF)  to  create the combined csv file for all of your run outputs for comparison. Be sure to have the variables set to annual in your IDF or your combined csv file will have issues.

BTW If I where you Niraj I would also report on Fan and possibly pump energy, as well as hours of discomfort. Also I would advise you to use Fanger thermal comfort control thermostats for your PCM models, rather a range of thermostat setpoints and drift points as a method to save a few thousand je+ jobs (e+simulations)...

All the Best 


Jeremiah D. Crossett
CleanTech Analytics
503-688-8951
www.cleantechanalytics.com


This document may contain valuable information proprietary to CleanTech Analytics which is private and confidential. It may not be shared, copied, stored or transmitted in any form without the prior written consent of CleanTech Analytics




On Tue, Jul 24, 2012 at 10:01 AM, Niraj Poudel <nirajpdl@xxxxxxxxx> wrote:
 

Hi all,


After making corrections recommended by Dr. Zhang. I am glad to say that the JE+ 1.3 runs with EPlus 7.1 were successful. 

However, I have a question regarding the .rvi file. I only want the annual heating and cooling energy as an output, If I define it in the .rvi file. as such:

eplusout.eso
eplusout.csv
Zone/Sys Sensible Cooling, Annual
Zone/Sys Sensible Heating, Annual
0

Do you think it would work? For instance, in the output "Sim results" next to the job ID, I only want the output for annual heating energy and annual cooling energy. I hope this makes sense.

Sincerely'
Niraj 


On Tue, Jul 24, 2012 at 12:06 PM, CleanTech Analytics <jeremiah@xxxxxxxxxxxxxxxxxxxxxx> wrote:
 

The files I sent where used successfully with jE+ 3.1 and Energy Plus 7.1, when both where in beta. I do however remember having some issues that I fixed by correcting some syntax similar to the advise provided by Dr Zhang.


If you send me the files I can take a look, or you might find use in my examples provided...

Best of luck-


Jeremiah D. Crossett
CleanTech Analytics

This document may contain valuable information proprietary to CleanTech Analytics which is private and confidential. It may not be shared, copied, stored or transmitted in any form without the prior written consent of CleanTech Analytics




On Tue, Jul 24, 2012 at 9:00 AM, Niraj Poudel <nirajpdl@xxxxxxxxx> wrote:
 

Dr. Zhang has helped me out and suggested that I remove any square brackets in my .imf file definition. For instance I had defined my insulation material as "Insulation [2]" and it looks like that specific square brackets are being recognized as a macro. 


Dr. Zhang also suggested that I double check the ##fileprefix line so that it is pointing to the correct folder. 

I will give both these recommendations of his a shot. I hope this will be helpful to anyone who is following this thread. 

Niraj 



On Tue, Jul 24, 2012 at 11:23 AM, Linda Lawrie <linda@xxxxxxxxxxxxxx> wrote:
 

Why not ask Dr Zhang?  As supporter of JE+, he should be able to help?



At 09:14 AM 7/24/2012, Niraj Poudel wrote:


I seem to be having the same problem with the newest version of JE+ or Eplus 7.1. I tried to run an older JE+ parametric run that ran successfully in the past. But when I run it now, using Eplus version 7.1 and JE+ version 1.3. I do not get any results. I am curious to know if Jeremiah has come across this problem as well?

If anyone else has come across this same issue. I would be glad to know how to tackle it.

Niraj

On Tue, Jul 24, 2012 at 10:56 AM, Amirhossein Ghoreishi < amirhosein_ghoreishi@xxxxxxxxx> wrote:
 

So many thanks for all helpful comments. I used the BIOPCM-HC.rvi for jEPlus. The project was validated successfully but after the simulation, the .cvs output file did not contain any information. I also tried the changes Dr. Li had suggested (modifier the .rvi file) but again no results were obtained. Any chance that I am using a wrong .rvi file, which is not compatible with the job I'd like the jE+ to carry out?




--
Niraj Poudel, Architectural Engineer.
PhD student, PDBE Program.
Clemson University, Clemson, SC.







--
Niraj Poudel, Architectural Engineer.
PhD student, PDBE Program.
Clemson University, Clemson, SC.






--
Niraj Poudel, Architectural Engineer.
PhD student, PDBE Program.
Clemson University, Clemson, SC.





__._,_.___


Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx

The primary EnergyPlus web site is found at:
http://www.energyplus.gov

The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/

Attachments are currently allowed but be mindful that not everyone has a high speed connection.  Limit attachments to small files.

EnergyPlus Documentation is searchable.  Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.




Your email settings: Individual Email|Traditional
Change settings via the Web (Yahoo! ID required)
Change settings via email: Switch delivery to Daily Digest | Switch to Fully Featured
Visit Your Group | Yahoo! Groups Terms of Use | Unsubscribe

__,_._,___