Even though you might not have any results, if you have checked jEplus to "keep all energyplus output files" under the execution tab then you must have a separate folder for each run. Now if you go into one of those folders and click on the .err file, you might know why you are not getting any results. Just mentioned that in case you already hadn't done so.
--On Thu, Aug 23, 2012 at 9:46 AM, Jeremiah Crossett <jcrossett@xxxxxxxxxxxxxxx> wrote:
I have had this issue before, and figured it out by checking the SIM-INDEX file for number of warnings-when there are warnings or severe crashes your runs may not actually be happening. What I realized is jE+ search strings will validate- even for an IDF that crashes. The process I used to find and fix issues is to open test the IDF in EP-Launch extensively before use in jE+, then to do a seed test of one run until it shows results.
Also for EP-Macro file names can not have any spaces. To be on the safe side I make sure that there are no spaces in any of my file names- so IDF name, IDF directory name, work directory names etc (spaces can use the underscore_symbol instead)All the best
Jeremiah D. Crossett | Senior Analyst | Phase Change Energy Solutions120 E. Pritchard St. | Asheboro, NC 27203 | Mobile 503-688-8951
On Thu, Aug 23, 2012 at 12:55 AM, bj.jay90 <bj.jay90@xxxxxxxxx> wrote:hi
I was trying to use JEplus for parametric simulation. although the project is successfully validated and it runs all the jobs, it does not seem to record any results. The simulation Results excel document is empty. Where am I going wrong ???
please help
Niraj Poudel, Architectural Engineer.PhD student, PDBE Program.Clemson University, Clemson, SC.