[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[EnergyPlus_Support] WaterHeater:Heatpump Object Energy use reporting.
- To: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Subject: [EnergyPlus_Support] WaterHeater:Heatpump Object Energy use reporting.
- From: Santiago Velez <santiagogvelez@xxxxxxxxx>
- Date: Thu, 21 Feb 2013 21:02:11 -0300
- Delivered-to: mailing list EnergyPlus_Support@xxxxxxxxxxxxxxx
- Delivery-date: Thu, 21 Feb 2013 17:02:15 -0700
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoogroups.com; s=echoe; t=1361491334; bh=e2ny1s+znxusdWaCHqHoWLddiEsxUw/wGKsIfcy58ds=; h=Received:Received:X-Yahoo-Newman-Id:X-Sender:X-Apparently-To:X-Received:X-Received:X-Received:X-Received:X-Received:X-Received:Message-ID:To:X-Originating-IP:X-eGroups-Msg-Info:From:X-Yahoo-Profile:Sender:MIME-Version:Mailing-List:Delivered-To:List-Id:Precedence:List-Unsubscribe:Date:Subject:Reply-To:X-Yahoo-Newman-Property:Content-Type; b=Yl+GusNpSRxWc8QNkH9QrDi5pq45EPwBRVuCLeMst5NdL6+kiInfskgCkz1QXIpEfB731EWBmnlRpHM9uDxnzUvjlfj6pfsmsqmFwWYcAV3/vVqtpwrWjxKHXfKl0FtjZSkOes3IWgVMw7QkAMDqkLWv55SdXqoenH3b8MYd110=
- Domainkey-signature: a=rsa-sha1; q=dns; c=nofws; s=echoe; d=yahoogroups.com; b=XLUPbNs1VQ1KxiNx21smimeJbUwuYU9rMISIk8KSgdu7IswGYkJ6+rosObM05F/dTriHy9T43te/G4lbL+mu7AMny2qQX9bXVg+Vh6aHfuGbGQo2oShW52vvHefxsjKUKb8ytayIu3rUIyubX+imJjtrx4SA0HBI/6Vfm76P5FM=;
- Envelope-to: linda@xxxxxxxxxxxxxx
- List-id: <EnergyPlus_Support.yahoogroups.com>
- List-unsubscribe: <mailto:EnergyPlus_Support-unsubscribe@yahoogroups.com>
- Mailing-list: list EnergyPlus_Support@xxxxxxxxxxxxxxx; contact EnergyPlus_Support-owner@xxxxxxxxxxxxxxx
- Reply-to: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Sender: EnergyPlus_Support@xxxxxxxxxxxxxxx
Dear Group, I am modelling an air cooled Chiller/Heatpump using a WaterHeater:Heatpump object for the heating mode connected to a dedicated Hot Water Loop (such as in HeatpumpWaterHeater.idf example file). Since this loop is connected on the supply side to a Water Heater object, there is no Heating energy reported in ABUPS; instead all this energy is accounted as Water systems.
So the first question is , is this last statement correct?
Second and less important question is, is there a way of telling E+ this is my buildings heating energy to be reported in ABUPS, so that I avoid using a separate Output:meter for heatpump's energy use and then having to subtract this energy from water systems which includes DHW as well? Read I/O Ref. related objects but didn't find any clues..
Thanks in advance.
Best,
Santiago.
__._,_.___
Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx
The primary EnergyPlus web site is found at:
http://www.energyplus.gov
The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/
Attachments are currently allowed but be mindful that not everyone has a high speed connection. Limit attachments to small files.
EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.
__,_._,___