[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[EnergyPlus_Support] Many coils in one AHU
- To: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Subject: [EnergyPlus_Support] Many coils in one AHU
- From: "FrancescoP" <direzionecontraria@xxxxxxxx>
- Date: Mon, 20 May 2013 07:35:39 -0000
- Delivered-to: mailing list EnergyPlus_Support@xxxxxxxxxxxxxxx
- Delivery-date: Mon, 20 May 2013 01:35:42 -0600
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoogroups.com; s=echoe; t=1369035341; bh=BoI5gdYSv+HIUhHN4m3p9QG6VRKyoHeJthjwmWDoIyE=; h=Received:Received:X-Yahoo-Newman-Id:X-Sender:X-Apparently-To:X-Received:X-Received:X-Received:X-Received:X-Received:X-Received:To:Message-ID:User-Agent:X-Mailer:X-Originating-IP:X-eGroups-Msg-Info:X-Yahoo-Post-IP:From:X-Yahoo-Profile:Sender:MIME-Version:Mailing-List:Delivered-To:List-Id:Precedence:List-Unsubscribe:Date:Subject:Reply-To:X-Yahoo-Newman-Property:Content-Type:Content-Transfer-Encoding; b=pqSzci+pPQo72lOgldAolym2c+tm7420k9cSWIdKg9NQWfn+8N3K3znH4LhXcYl9luS+DOcPwYQ71JCQVKV1y90YL+jnA3hXgGCggKOPTUQo6ydtkteMBBmM3PbF75fhxiS/EXtR54jET7j6OnaCUg7IwrxuGhdQFZY9BfixHXE=
- Domainkey-signature: a=rsa-sha1; q=dns; c=nofws; s=echoe; d=yahoogroups.com; b=fTe3CZbHEw3E4GCXz0vXwI2Qp2B1tjgHkvDbHRJQSyNi4ClU42oY1AfGKG8IMSIh6XNl0kv/VA4ksKURzLGoe/Ctz+s0iowJSTM5nr7HR7XGyAJj7FaHM2D5t8j5/X+clEOCHy2yQIh6uZYBMd3dHaFZD3kkrC7lFvDj/iR/XiU=;
- Envelope-to: linda@xxxxxxxxxxxxxx
- List-id: <EnergyPlus_Support.yahoogroups.com>
- List-unsubscribe: <mailto:EnergyPlus_Support-unsubscribe@yahoogroups.com>
- Mailing-list: list EnergyPlus_Support@xxxxxxxxxxxxxxx; contact EnergyPlus_Support-owner@xxxxxxxxxxxxxxx
- Reply-to: EnergyPlus_Support@xxxxxxxxxxxxxxx
- Sender: EnergyPlus_Support@xxxxxxxxxxxxxxx
- User-agent: eGroups-EW/0.82
Hello,
I have to model a dehumidification system (an AHU without outdoor air, only recirculation) in which there are a water cooling coil, a DX cooling coil, a DX heating coil, and another water cooling coil.
I begin to model in DesignBuilder, then I export the .idf file in EnergyPlus. As you can read at the following link, modeling such a system directly in DesignBuilder isn't possible:
http://www.designbuilder.co.uk/index.php?option=com_forum&Itemid=1&page=viewtopic&p=12704#12704
What is the best way, in your opinion?
In DesignBuilder shall I begin with an Unitary heat pump or with a Generic Air loop?
Best Regards
------------------------------------
Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx
The primary EnergyPlus web site is found at:
http://www.energyplus.gov
The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/
Attachments are currently allowed but be mindful that not everyone has a high speed connection. Limit attachments to small files.
EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.
Yahoo! Groups Links
<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/EnergyPlus_Support/
<*> Your email settings:
Individual Email | Traditional
<*> To change settings online go to:
http://groups.yahoo.com/group/EnergyPlus_Support/join
(Yahoo! ID required)
<*> To change settings via email:
EnergyPlus_Support-digest@xxxxxxxxxxxxxxx
EnergyPlus_Support-fullfeatured@xxxxxxxxxxxxxxx
<*> To unsubscribe from this group, send an email to:
EnergyPlus_Support-unsubscribe@xxxxxxxxxxxxxxx
<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/