[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[EnergyPlus_Support] Heat recovery - No on-site heat value in SummaryReports
- To: <EnergyPlus_Support@xxxxxxxxxxxxxxx>
- Subject: [EnergyPlus_Support] Heat recovery - No on-site heat value in SummaryReports
- From: "farhang.tahmasebi@xxxxxxxxx [EnergyPlus_Support]" <EnergyPlus_Support@xxxxxxxxxxxxxxx>
- Date: 21 Jun 2014 02:38:11 -0700
- Delivered-to: mailing list EnergyPlus_Support@xxxxxxxxxxxxxxx
- Delivery-date: Sat, 21 Jun 2014 03:38:20 -0600
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoogroups.com; s=echoe; t=1403343492; bh=qOQ5ZenFVaAIJJbFk4xZqGJwbeRWR8j8ZhYPg7Yz3+c=; h=Received:Received:X-Yahoo-Newman-Id:X-Sender:X-Apparently-To:X-Received:X-Received:X-Received:X-Received:X-Received:X-Received:X-Received:To:Message-ID:X-Mailer:X-Original-From:X-Originating-IP:X-eGroups-Msg-Info:X-Yahoo-Post-IP:From:X-Yahoo-Profile:Sender:MIME-Version:Mailing-List:Delivered-To:List-Id:Precedence:List-Unsubscribe:Date:Subject:Reply-To:X-Yahoo-Newman-Property:Content-Type; b=Nczf04AkTgq9tW2hg/bzsXwQZA9zBA7QlBvNm27VEKDlT+PVW3WvmoD2mjrefkRceifSVT+iyPKvvvCTyYz16HDUb/3i09TQLxGzJUpDWCTQP8hSxhSk3mCPyqxrINdGsLSOu0qRr1sc7v32GDcrRs1NT1HfxYMlNyjMURSBaWc=
- Domainkey-signature: a=rsa-sha1; q=dns; c=nofws; s=echoe; d=yahoogroups.com; b=OlnwVg1Ha6geD/ZC9UxMKx3jMDdvg9IwjwxgDEc/1enMmno4MaXG3wE3RxUf65Wfffp5DvHSlJcF7yJdKW/h1Ge9C2U3B7QU0iOFnwQz76U5vIoO8KF/rqfavktQYa+a4tLmDWD/zmvmEx8XwWo4y+FWTTjSXMX76PiW9OOVprE=;
- Envelope-to: linda@xxxxxxxxxxxxxx
- List-id: <EnergyPlus_Support.yahoogroups.com>
- List-unsubscribe: <mailto:EnergyPlus_Support-unsubscribe@yahoogroups.com>
- Mailing-list: list EnergyPlus_Support@xxxxxxxxxxxxxxx; contact EnergyPlus_Support-owner@xxxxxxxxxxxxxxx
- Reply-to: EnergyPlus_Support@xxxxxxxxxxxxxxx
Hi,
Using the class HVACTemplate:Zone:IdealLoadsAirSystem (in EnergyPlus 8.1) to model ventilation heat recovery with an arbitrary efficiency, air to air heat recovery values in the Annual Building Utility Performance Summary Report - On-Site Thermal Sources are zero. Does it make sense? I mean, are these values for something else other than ventilation heat recovery or they are not filled by mistake?
Best,
Farhang Tahmasebi
Vienna University of Technology
__._,_.___
Posted by: farhang.tahmasebi@xxxxxxxxx
Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx
The primary EnergyPlus web site is found at:
http://www.energyplus.gov
The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/
Attachments are currently allowed but be mindful that not everyone has a high speed connection. Limit attachments to small files.
EnergyPlus Documentation is searchable. Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.
__,_._,___