[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [EnergyPlus_Support] Confusion in the PEOPLE object?





Could you send me the values of the schedules???

Oscar

On Aug 19, 2014 11:52 PM, "nick.novelli@xxxxxxxxx [EnergyPlus_Support]" <EnergyPlus_Support@xxxxxxxxxxxxxxx> wrote:
 

Hello,

I'm getting severe errors from internal gains calculations, the PEOPLE object, and it appears to be that the e+ engine is confused about which field is which:


The .err file is telling me that I should be using values of model types (i.e., "Fanger," "Pierce," etc) for my clothing insulation schedule name and air velocity schedule name. These are warnings, but the engine breaks down at a severe error where "CLOTHINGINSULATIONSCHEDULE" isn't recognized as a clothing insulation calculation method. I've tried the different configurations from the inputOutputReference with no success. Has anyone run into these issues?


Here's my people object:


People,

    CORE-PEOPLE,             !- Name

    AllCoreZones,            !- Zone or ZoneList Name

    BLDG_OCC_SCH,            !- Number of People Schedule Name

    Area/Person,             !- Number of People Calculation Method

    ,                        !- Number of People

    ,                        !- People per Zone Floor Area {person/m2}

    OccDensity[],            !- Zone Floor Area per Person {m2/person}

    0.3000,                  !- Fraction Radiant

    AUTOCALCULATE,           !- Sensible Heat Fraction

    ACTIVITY_SCH,            !- Activity Level Schedule Name

    3.82E-8,                 !- Carbon Dioxide Generation Rate {m3/s-W}

    No,                      !- Enable ASHRAE 55 Comfort Warnings

    ZoneAveraged,            !- Mean Radiant Temperature Calculation Type

    ,                        !- Surface Name/Angle Factor List Name

    WORK_EFF_SCH,            !- Work Efficiency Schedule Name

    ClothingInsulationSchedule,  !- Clothing Insulation Calculation Method

    ,                        !- Clothing Insulation Calculation Method Schedule Name

    CLOTHING_SCH,            !- Clothing Insulation Schedule Name

    AIR_VELO_SCH,            !- Air Velocity Schedule Name

    FANGER;                  !- Thermal Comfort Model 1 Type


_________________________

And here's the .err output: 


   ** Warning ** GetInternalHeatGains: People="CORE-PEOPLE", invalid Clothing Insulation Schedule Name Option=CLOTHING_SCH
   **   ~~~   ** Valid Values are "Fanger", "Pierce", "KSU", "AdaptiveASH55", "AdaptiveCEN15251"
   ** Warning ** GetInternalHeatGains: People="CORE-PEOPLE", invalid Air Velocity Schedule Name Option=AIR_VELO_SCH
   **   ~~~   ** Valid Values are "Fanger", "Pierce", "KSU", "AdaptiveASH55", "AdaptiveCEN15251"
   ** Severe  ** GetInternalHeatGains: People="CORE-PEOPLE", invalid Clothing Insulation Calculation Method entered=CLOTHINGINSULATIONSCHEDULE
   ** Severe  ** GetInternalHeatGains: People="CORE-PEOPLE", blank Clothing Insulation Calculation Method Schedule Name is required for this item.

Thanks for the thoughts!

Nick.


 



__._,_.___

Posted by: Oscar Hernandez <eng.ohw@xxxxxxxxx>


Primary EnergyPlus support is found at:
http://energyplus.helpserve.com or send a message to energyplus-support@xxxxxxxx

The primary EnergyPlus web site is found at:
http://www.energyplus.gov

The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/

Attachments are currently allowed but be mindful that not everyone has a high speed connection.  Limit attachments to small files.

EnergyPlus Documentation is searchable.  Open EPlusMainMenu.pdf under the Documentation link and press the "search" button.




Visit Your Group
Yahoo! Groups
PrivacyUnsubscribeTerms of Use

__,_._,___