RE: [EnergyPlus_Support] Changing the batch file "RunEPlus.bat"



Linda

 

Thanks for your solution, but it is not working either. I copied RunReadESO to PostProcess folder. I guess, in the main EXE File (EnergyPlus.exe), there is at least one call to eplusout.eso and probably I am missing some prefix like %program_path% somewhere in the batch file.

 

You might say, there’s call to eplusout.eso at :L2 part of the batch file. My understanding is that, RunReadESO is for post-processing and not necessarily needed for running EnergyPlus. So I REMed it, but doesn’t work.

 

The error message still is the same, like:

May I know, where is eplusout.eso referenced? Is that in ReadVarsESO or EnergyPlus.exe?

 

Anyway, thanks for your help.

 

Regards

 

Monjur

 

-----Original Message-----
From: Linda Lawrie [mailto:linda@xxxxxxxxxx]
Sent: 04 November 2002 17:07
To: EnergyPlus_Support@xxxxxxxxxxxxxxx
Subject: Re: [EnergyPlus_Support] Changing the batch file "RunEPlus.bat"

 

At 10:56 AM 11/4/2002, Monjur M Mourshed wrote:


 IF EXIST RunReadESO.bat goto L1
 copy %post_proc%\RunReadESO.bat RunReadESO.bat

:L1
 IF EXIST ReadVarsESO.exe goto L2
 copy %post_proc%\ReadVarsESO.exe ReadVarsESO.exe

:L2 
 CALL %program_path%\RunReadESO
 IF EXIST eplusout.eso MOVE eplusout.eso %output_path%\%1.eso
 IF EXIST eplusout.rdd MOVE eplusout.rdd %output_path%\%1.rdd
 IF EXIST eplusout.dbg MOVE eplusout.dbg %output_path%\%1.dbg
 IF EXIST eplusout.eio MOVE eplusout.eio %output_path%\%1.eio
 IF EXIST eplusout.err MOVE eplusout.err %output_path%\%1.err


Without looking too deeply or trying it, I would offhand say you need to copy or make a RunReadESO.bat file in the Post Processing folder where the ReadVarsESO file is.

And since I just looked at our Standard RunEPLus -- I'd say it's not working correctly!  Hmmm.

The file RunReadESO.bat needs to be in the PostProcess folder according to this scenario -- and it isn't.  Perhaps putting it there will make this all work>

The error 'RunReadESO' is not recognizable is a Windows 2000 (or other?) message for "I couldn't find this file".

Hope this helps.




Linda

EnergyPlus WebSite: http://www.energyplus.gov
Owner: EnergyPlus_Support list
Member: EnergyPlus Development Team




To unsubscribe from this group, send an email to:
EnergyPlus_Support-unsubscribe@xxxxxxxxxxxxxxx

The primary EnergyPlus web site is found at:
http://www.energyplus.gov

The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/






Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.


Yahoo! Groups Sponsor
ADVERTISEMENT

To unsubscribe from this group, send an email to:
EnergyPlus_Support-unsubscribe@xxxxxxxxxxxxxxx

The primary EnergyPlus web site is found at:
http://www.energyplus.gov

The group web site is:
http://groups.yahoo.com/group/EnergyPlus_Support/






Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
Email file not found:
C:\Users\lklawrie\Downloads\Embedded\image0017.jpg