ÂThere is no meaning in integrating any measured data into EPlus simulation without the complete set of environment data.
EPlus only has one value for a large wall, for example. Where do you place the sensor to get the wall temperature?
Dr. Ooi has investigate many cases in his PhD research. Local weather data helped to provide some results.
What you should do is to find a day in the weather file which has the same (as near as possible for three OD temperature) condition as the day and time when the measurements were make and then compare the values. This was done by curve matching using the resultViewer.
Hope this help
Dr.Li.
--- In EnergyPlus_Support@xxxxxxxxxxxxxxx, "Yan, Ying" <yiy11005@...> wrote:
>
> Hello everyone,
>
> I built a simulation model of a building. Now we obtained several real data from sensors installed in the building such as the temperature, the humidity ratio, and etc. I want to replace part of the simulation model by these real data which means the hybrid simulation model with real data will get closer to the real building. My question is whether I can replace part of the simulation model by real data. For instance, I knew the real data of the mixed air temperature of the AHU and the discharge air temperature of the AHU. How can I force these two variables to be the real data in my simulation model? Thank you for giving me some suggestions!
>
> ----------------------------------------
> Best Regards
>
> Ying Yan
>
> Graduate Student
> Electrical & Computer Engineering
> School of Engineering
> University of Connecticut
>